Results 101 to 110 of about 1,999 (210)

Studi Karakteristik Tegangan Tembus DC Polaritas Positif pada Gas Nitrogen (N2) [PDF]

open access: yes, 2017
Insulation of Sulfur hexafluoride (SF6) gas, nitrogen (N2) gas and Carbon Dioxide (CO2) gas usually used in circuit breaker. Sulfur hexafluoride (SF6) gas is widely used in high-voltage system.
Murdiya, F. '. (Fri)   +1 more
core  

Individual Professional Practice in the Company [PDF]

open access: yes, 2018
Tato bakalářská práce obsahuje popis odborné praxe absolvované u firmy ABB s. r. o., OPC Ostrava. V této práci je uvedené odborné zaměření pobočky společnosti v Ostravě. Dále je zde popis mé pracovní pozice a náplň práce po dobu praxe.
Vávra, Lukáš
core  

Research on Photoacoustic Ultrasonic Dual Mode GIS Gas Tomography Technology

open access: yesJournal of Harbin University of Science and Technology
Recently, environmentally friendly insulating gases represented by (CF 3 ) 2 CFCN have been widely used in high-voltage insulated switchgear (GIS) in various countries due to their low global warming potential and ozone free characteristics.
TANG Bingnan, ZHOU Yao, WANG Anjing
doaj   +1 more source

A DFT Calculation of Fluoride-Doped TiO2 Nanotubes for Detecting SF6 Decomposition Components

open access: yesSensors, 2017
Gas insulated switchgear (GIS) plays an important role in the transmission and distribution of electric energy. Detecting and analyzing the decomposed components of SF6 is one of the important methods to realize the on-line monitoring of GIS equipment ...
Xiaoxing Zhang   +3 more
doaj   +1 more source

Effect of water on electrical properties of Refined, Bleached, and Deodorized Palm Oil (RBDPO) as electrical insulating material [PDF]

open access: yes, 2012
This paper describes the properties of refined, bleached, deodorized palm oil (RBDPO) as having the potential to be used as insulating liquid. There are several important properties such as electrical breakdown, dielectric dissipation factor, specific ...
Arief, Yanuar Zulardiansyah   +1 more
core  

Construction of abatement cost curves: The case of F-gases [PDF]

open access: yes
Most of scientific research on Greenhouse Gases (GHG) focuses on CO2 emissions. But non-CO2 gases (mainly F-gases in the form of HFCs, PFCs, and SF6) are more potent at trapping heat within the atmosphere. Currently, F-gases constitute a small proportion
Halkos, George
core   +1 more source

Semi-Supervised Learning-Based Partial Discharge Diagnosis in Gas-Insulated Switchgear

open access: yesIEEE Access
Effective monitoring and diagnosis of partial discharge (PD) in power equipment are crucial for maintenance, particularly given the expectations of significant increases in energy generation and consumption. Although deep neural networks have been widely
Ho Trong Tai   +3 more
doaj   +1 more source

Charge Accumulation Characteristics of SF6-Epoxy Interface Under Negative Repetitive Nanosecond Pulses

open access: yesCSEE Journal of Power and Energy Systems
Repetitve nanosecond impulses in gas-insulated metal-enclosed switchgear (GIS) are likely to trigger inside flashover. Interface charges on the spacer in GIS are considered one of the main factors damaging insulation performance and may be induced by ...
Shaocong Wu   +6 more
doaj   +1 more source

Condition assessment method of GIS disconnector based on vibration- thermal-electrical multi-parameter signal characteristics

open access: yes电力工程技术
The disconnector fault in gas insulated switchgear (GIS) is commonly caused by the combined effects of mechanical, thermal, and electrical factors. Throughout the progression from defect development to a severe fault, various signals, including abnormal ...
ZHOU Xiu   +5 more
doaj   +1 more source