Results 121 to 130 of about 5,182 (292)
We introduce an additively manufactured bioreactor with a perfusion flow system and integrated temperature and pH sensors for skeletal muscle tissue biofabrication. The bioreactor's performance was evaluated by assessing the viability, spreading of the myoblast cells in a printed scaffold, and contraction of the isolated murine musculi interossei ...
Lys Sprenger +9 more
wiley +1 more source
Here, two types of electronic components are presented: a strain sensor and a stable resistor. Electrofluids properties are tuned to match these behaviors by selecting the type of filler. We show that the morphology of the filler together with its oxygen content are the key parameters to create electrical and mechanical networks with distinct responses.
Dominik S. Schmidt +4 more
wiley +1 more source
Initiating, the equal-area criterion by Kind and the leader progression model are analyzed as insulator flashover models for overhead line insulators.
Goll, F., Witzmann, R., Neumann, C., Imamovic, D
core
This paper presents experimental results on the transient response of a buried insulated wire subjected to fast transient signals. It reports measurements of voltage and current at the sending end, as well as the voltage at the receiving end of the ...
Rachidi-Haeri, Farhad +2 more
core +1 more source
Liquid metal additives are processed in elastomer host resulting in highly conductive and stretchable composites. The material functions as a piezoresistive sensor with minimal drift, low stiffness, and enhanced operating range. The film can replace wires to charge a mobile phone at ∼350% strain and monitors bodily motion in real‐time via a portable ...
Patryk Wojciak +3 more
wiley +1 more source
Nondestructive Measurement of Residual Stress on Epoxy Insulators Using Thermoelastic Method
Residual stress is inevitable in epoxy insulators, which easily leads to small cracks and even insulation breakdown during the operation of gas‐insulated transmission line (GIL)/gas‐insulated switchgear (GIS).
Hucheng Liang, Bei Chu, Boxue Du
doaj +1 more source
This article highlights the development of robust and high‐performance flexible and stretchable biosensors that maintain long‐term functionality and optimal electrical conductivity under mechanical deformation, utilizing sustainable and cost‐effective manufacturing principles.
Mousa H. Aldosari, Ahyeon Koh
wiley +1 more source
This paper examines the modeling approaches used to analyze the electric field distribution in high-voltage direct-current gas-insulated systems (HVDC-GISs) used for the acceleration grid power supply (AGPS) of neutral beam injectors (NBIs).
Francesco Lucchini +4 more
doaj +1 more source
Aerosol Jet Printing (AJP) has emerged as a versatile additive manufacturing technique for high‐resolution, conformal, and multi‐material printing. This review highlights advances in printable materials, substrate compatibility, post‐processing, characterization, and process innovations, while critically discussing current challenges and future ...
Chandrachur Chatterjee +2 more
wiley +1 more source
High‐Performance Piezoelectric Nanogenerators Based on Wurtzite BeO Nanowire Arrays
This study demonstrates high‐performance piezoelectric nanogenerators based on 1D BeO nanowire arrays. The BeO nanowires exhibit a high piezoelectric coefficient (∼15.8 pm V−1) and deliver an output voltage of ∼26.1 V and power density of ∼0.32 µW cm−2.
Yoonseo Jang +7 more
wiley +1 more source

