Results 21 to 30 of about 2,695 (261)
Transient impedance of grounding system with impulse superimposed sinewave
Investigating the transient performance of grounding systems subject to lightning (impulse or impulse superimposed sinewave) is valuable for protecting the power system and maintaining the system operation.
Sherif Ghoneim +2 more
doaj +1 more source
Percutaneous radiofrequency ablation for hepatic tumors: factors affecting baseline impedance
PurposeWe aimed to evaluate factors that affect baseline impedance of percutaneous radiofrequency ablation.MethodsIn this retrospective study, we analyzed 51 patients with 55 hepatic tumors from November 2015 until April 2018.
Sungjun Hwang +4 more
doaj +1 more source
Acoustic ground impedance meter [PDF]
A compact, portable instrument has been developed to measure the acoustic impedance of the ground, or other surfaces, by direct pressure-volume velocity measurement. A Helmholtz resonator, constructed of heavy-walled stainless steel but open at the bottom, is positioned over the surface having the unknown impedance.
openaire +2 more sources
High current field test of impulse transient characteristics of substation grounding grid
It is significant to research the impulse characteristics of substation grounding grid for its optimal design and safe and stable operation. In order to obtain the impulse transient characteristics of substation grounding grid under lightning impulse ...
Xuefang Tong, Xiaohui Dong, Bo Tan
doaj +1 more source
When a high impedance grounding fault occurs in the power cables, the current at the fault point is extremely low and the fault characteristics are too weak to be detected by the reflectometry. Interfered by the multiple reflections, the fault is hard to
Shurong Li +5 more
doaj +1 more source
Overview of Transient Simulations of Grounding Systems under Surge Conditions
The present paper gives an overview of modelling methods of standard grounding systems under surge conditions, using the non-uniform transmission line approach.
Tomasz Kisielewicz, Milton Cuenca
doaj +1 more source
Abnormal circulating current induced by sheath grounding faults in cross-bonded high-voltage cables is a major cause of single-phase grounding faults.
Hang Wang +5 more
doaj +1 more source
Circulating microRNAs as biomarkers of cachexia and sex‐specific cancer in senior dogs. In 25 client‐owned dogs, four circulating miRNAs (miR‐15a, miR‐15b, miR‐16, miR‐140) were downregulated in cachexia, with miR‐16 the strongest individual biomarker (AUC = 0.899).
Soon‐Seok Park +6 more
wiley +1 more source
UiO‐66(Zr) metal–organic frameworks are chemically stable, biocompatible, and highly tunable nanomaterials. Their modular structure enables controlled drug delivery, multimodal bioimaging, and light‐activated photodynamic therapy, supporting integrated diagnostic and therapeutic (theranostic) applications in cancer and biomedical research.
Veronika Huntošová +2 more
wiley +1 more source
This article mainly introduces the impedance based single-phase grounding fault location method for distribution networks, including its theoretical basis, algorithm steps, and simulation verification.
Sha Wang, Shengkai Wei
doaj +1 more source

