Results 51 to 60 of about 38,130 (219)

Rapid Fabrication of Self‐Propelled and Steerable Magnetic Microcatheters for Precision Medicine

open access: yesAdvanced Materials, EarlyView.
A rapid Joule heating fabrication method for the production of self‐propelling, adaptive microcatheters, with tunable stiffness and integrated microfluidic channels is presented. Demonstrated through three microrobotic designs, including a steerable guiding catheter, an untethered wave‐crawling TubeBot, and a distal‐end propelled microcatheter, it was ...
Zhi Chen   +5 more
wiley   +1 more source

Kelvin Probe Force Microscopy in Bionanotechnology: Current Advances and Future Perspectives

open access: yesAdvanced Materials, EarlyView.
Kelvin probe force microscopy (KPFM) enables the nanoscale mapping of electrostatic surface potentials. While widely applied in materials science, its use in biological systems remains emerging. This review presents recent advances in KPFM applied to biological samples and provides a critical perspective on current limitations and future directions for
Ehsan Rahimi   +4 more
wiley   +1 more source

LEAD: Literature Enhanced Ab Initio Discovery of Nitride Dusting Layers for Enhanced Tunnel Magnetoresistance and Lower Resistance Magnetic Tunnel Junctions

open access: yesAdvanced Materials, EarlyView.
Magnetic tunnel junctions (MTJs) using MgO tunnel barriers face challenges of high resistance‐area product and low tunnel magnetoresistance (TMR). To discover alternative materials, Literature Enhanced Ab initio Discovery (LEAD) is developed. The LEAD‐predicted materials are theoretically evaluated, showing that MTJs with dusting of ScN or TiN on ...
Sabiq Islam   +6 more
wiley   +1 more source

Distributed Power Hardware-in-the-Loop Testing Using a Grid-Forming Converter as Power Interface

open access: yesEnergies, 2020
This paper presents an approach to extend the capabilities of smart grid laboratories through the concept of Power Hardware-in-the-Loop (PHiL) testing by re-purposing existing grid-forming converters.
Steffen Vogel   +6 more
doaj   +1 more source

Localized Temperature Monitoring in Mouse Brain during Light Delivery via a Non‐Planar Tapered Fiber‐Integrated µRTD Sensor

open access: yesAdvanced Materials, EarlyView.
We report a multifunctional tapered optical fiber integrating a conformal micro‐resistance temperature detector (µRTD) for local, real‐time thermometry during optical stimulation. The platform combines light‐delivery and temperature sensing within a minimally invasive footprint, enabling detection of sub‐degree cortical heating under representative ...
Antonio Balena   +6 more
wiley   +1 more source

Self‐Powered Flexible Triboelectric‐Gated Ion‐Gel Transistor for Neuromorphic Tactile Sensing and Human Activity Recognition

open access: yesAdvanced Materials, EarlyView.
A fully flexible ion‐gel‐gated graphene‐channel transistor driven by a triboelectric nanogenerator enables self‐powered tactile sensing and synaptic learning. Mimicking spike‐rate‐dependent plasticity, the device exhibits frequency‐selective potentiation and depression, supporting rate‐coded neuromorphic computation even under flex.
Hanseong Cho   +3 more
wiley   +1 more source

In Vivo Monitoring of Thrombo‐Inflammatory Biomarkers via Molecularly Imprinted Polymer‐Integrated Hydrogel Microneedles

open access: yesAdvanced Materials, EarlyView.
A wearable electrochemical microneedle patch integrates Prussian Blue redox transduction with molecularly imprinted polymer recognition for reagent‐free sampling and detection of thrombo‐inflammatory biomarkers in dermal interstitial fluid. The platform tracks thrombin and inflammatory cytokines with sensitive in vitro, ex vivo, and in vivo performance,
Mahmoud Ayman Saleh   +11 more
wiley   +1 more source

REAL-TIME SIMULATION FOR PROTECTION AND SUBSTATION CONTROL WITH MATLAB / SIMULINK

open access: yesDiyala Journal of Engineering Sciences, 2016
This paper presents the design of a simple real-time simulator to protection electrical power system tests, whose the operation principle is based on closed feedback in the loop.
Jamal A. Hameed
doaj   +1 more source

Neuromorphic Electronics for Intelligence Everywhere: Emerging Devices, Flexible Platforms, and Scalable System Architectures

open access: yesAdvanced Materials, EarlyView.
The perspective presents an integrated view of neuromorphic technologies, from device physics to real‐time applicability, while highlighting the necessity of full‐stack co‐optimization. By outlining practical hardware‐level strategies to exploit device behavior and mitigate non‐idealities, it shows pathways for building efficient, scalable, and ...
Kapil Bhardwaj   +8 more
wiley   +1 more source

Path‐Decoupled Cation‐Eutaxy III–V van der Waals Memristive Semiconductors for Mitigating the Neuromorphic Accuracy‐Energy Trade‐off

open access: yesAdvanced Materials, EarlyView.
Path‐decoupled III–V van der Waals memtransistors spatially separate ionic and electronic transport to overcome the conventional trade‐off between accuracy and energy in neuromorphic hardware. Mobile K+ ions in the vdW gaps set a wide conductance window, Gmax/Gmin, while gate‐tunable hole conduction lowers programming energy, enabling reliable ...
Jihong Bae   +13 more
wiley   +1 more source

Home - About - Disclaimer - Privacy