Results 61 to 70 of about 8,491 (214)

Near-infrared spectroscopy parameters in patients undergoing continuous venovenous hemodiafiltration [PDF]

open access: yes, 2019
Objective To investigate the impacts of continuous venovenous hemodiafiltration on the microcirculation in patients with acute kidney injury. Methods A prospective observational pilot study conducted in a 40-bed, open clinical-surgical intensive care ...
Miguel Cendoroglo Neto (6379652)   +8 more
core   +1 more source

Supplementary Material for: Success of pregnancy in a patient on high volume hemodiafiltration with citrate-acidified dialysate [PDF]

open access: yes, 2023
Although pregnancy in dialysis patients is rare, recent reports in the literature have shown improvement in pregnancy outcome in this population. Increasing doses of dialysis has led to improvement in fetal prognosis, but recommendations are still ...
Fay S. (14826667)   +5 more
core   +1 more source

Differences in Dialysis Efficacy Have Limited Effects on Protein-Bound Uremic Toxins Plasma Levels over Time

open access: yesToxins, 2019
The protein-bound uremic toxins para-cresyl sulfate (pCS) and indoxyl sulfate (IS) are associated with cardiovascular disease in chronic renal failure, but the effect of different dialysis procedures on their plasma levels over time is poorly studied ...
Detlef H. Krieter   +4 more
doaj   +1 more source

Sodium modeling in hemodiafiltration

open access: yesKidney International, 1991
A computer model was developed to simulate sodium and water kinetics during hemodiafiltration (HDF), acetate-free biofiltration (AFB) and hemodialysis (HD). Multiple regression analysis of the results of 3,240 simulated applications of the model (1,620 HDF, 1,080 AFB, 540 HD) showed that, during HDF and AFB, there is a close correlation (R2 = 0.92 and ...
Pedrini, Luciano A.   +4 more
openaire   +2 more sources

Machine learning‐based predictive models versus traditional risk scores in hemodialysis patients with comorbid urolithiasis

open access: yesPrecision Medical Sciences, Volume 15, Issue 2, Page 80-90, June 2026.
Machine learning‐based predictive models outperform traditional risk scores in hemodialysis patients with comorbid urolithiasis by capturing nonlinear, dialysis‐specific interactions. These approaches enable more accurate prediction of stone recurrence, sepsis, hospitalization, and mortality, supporting personalized risk stratification and precision ...
Dipal Chaulagain   +4 more
wiley   +1 more source

Endotoxin-Retentive Filters for the Online Preparation of Ultrapure Dialysis Fluid and Non-Pyrogenic Substitution Fluid: A Critical Review and Reference Guide

open access: yesMembranes
Poor water treatments and concentrates to prepare dialysis fluids favor bacterial growth-producing pyrogens (e.g., endotoxins) that may cross hemodialysis, particularly high-flux, membranes.
Gerardo Catapano   +4 more
doaj   +1 more source

Combination of Multiple Hemodialysis Modes: Better Treatment Options for Patients Under Maintenance Hemodialysis

open access: yesTherapeutics and Clinical Risk Management, 2021
Zhi-Yong Zhang, Ming-Xu Li, Hai Yu, Jun Zhao, Feng-Lin Xiao, Fang Xuan, Yi-Xin Zhao Department of Nephrology, The Sixth Medical Center of PLA General Hospital, Beijing, People’s Republic of ChinaCorrespondence: Ming-Xu LiDepartment of Nephrology ...
Zhang ZY   +6 more
doaj  

Effect of increased convective clearance by on-line hemodiafiltration on all cause and cardiovascular mortality in chronic hemodialysis patients – the Dutch CONvective TRAnsport STudy (CONTRAST): rationale and design of a randomised controlled trial [ISRCTN38365125]

open access: yesCurrent Controlled Trials in Cardiovascular Medicine, 2005
Background The high incidence of cardiovascular disease in patients with end stage renal disease (ESRD) is related to the accumulation of uremic toxins in the middle and large-middle molecular weight range. As online hemodiafiltration (HDF) removes these
Nubé Menso J   +7 more
doaj   +1 more source

Comparison of Biocompatibility and Efficacy of Regional Citrate Anticoagulation and Unfractionated Heparin During Expanded Hemodialysis With a Medium Cut‐Off Membrane: A Randomized Trial

open access: yesArtificial Organs, Volume 50, Issue 6, Page 809-812, June 2026.
In a randomized cross‐over trial, regional citrate anticoagulation provided superior biocompatibility over full‐dose unfractionated heparin during expanded hemodialysis with significantly lower activation of complement, granulocytes, and platelets without affecting dialysis efficiency. ABSTRACT Background Regional citrate anticoagulation (RCA) improves
Marija Malgaj Vrečko   +7 more
wiley   +1 more source

Costs and Outcomes in Hemodialysis and Hemodiafiltration [PDF]

open access: yes, 2011
Both survival and quality of life (QoL) are poor in patients on hemodialysis. Earlier studies have shown their QoL to be lower than in patients with for instance chronic heart failure, arthritis and metastatic colon cancer.
Mazairac, A.H.A.
core  

Home - About - Disclaimer - Privacy