Results 11 to 20 of about 73,716 (295)
Effect of Impulse Polarity on a New Grounding Device with Spike Rods (GDSR)
The characterizations of grounding systems subjected to high impulse conditions are known to be dependent on the polarity, current to peak time and discharge time, as well as the electrical properties of the soil, and the grounding electrodes themselves.
Abdul Wali Abdul Ali +2 more
doaj +2 more sources
A partial discharge (PD) measuring system has been deployed in order to identify and measure PD in a high voltage (HV) cable joint under impulse and superimposed voltages under laboratory conditions. The challenge is to enable the detection of PD during the impulse conditions. The method of measurement has been investigated by introducing an artificial
Wu, J. (author) +3 more
openaire +4 more sources
In many publications, the characteristics of practical earthing systems were investigated under conditions involving fast-impulse currents of different magnitudes by field measurements.
Abdul Wali Abdul Ali +4 more
doaj +2 more sources
High power impulse magnetron sputtering under industrial conditions
In this thesis, the recent development step of magnetron sputtering, termed high power impulse magnetron sputtering (HiPIMS) has been studied. Compared to conventional magnetron sputtering HiPIMS provides a higher plasma density which can ionise the sputtered material.
Samuelsson, Mattias
openaire +2 more sources
Abstract There have been many studies in the pasts, which showed that under high impulse conditions, soil ionization process around the electrode would occur, which results in lower resistance and lower transient voltage on the electrode.
HA Hamid +7 more
openaire +1 more source
Possibility of using RIT technology in the ground conditions of Vietnam [PDF]
The article compares engineering and geological conditions in the coastal areas of Vietnam and Tunisia. A sufficiently high similarity of soil structure and their physical and mechanical properties was noted.
Kharin Yury
doaj +1 more source
Impulse response and electric field computation of various rod electrodes
Ionisation process has been known to occur in soil, when earth electrodes are subjected under high impulse conditions. In this paper, experimental results on impulse response of various earth electrodes, namely a conventional copper rod electrode, and ...
Nur Farahi Idris +2 more
doaj +1 more source
High-latitude observations of impulse-driven ULF pulsations in the ionosphere and on the ground [PDF]
International audienceWe report the simultaneous observation of 1.6?1.7 mHz pulsations in the ionospheric F-region with the CUTLASS bistatic HF radar and an HF Doppler sounder, on the ground with the IMAGE and SAMNET magnetometer arrays, and in the ...
Menk, F. W. +14 more
core +1 more source
Seasonal Influences on the Impulse Characteristics of Grounding Systems for Tropical Countries
One of the most important parameters of the performance of grounding systems is the soil resistivity. As generally known, the soil resistivity changes seasonally, hence the performance of grounding systems, at DC and under high impulse conditions.
Muhd Shahirad Reffin +6 more
doaj +1 more source
High‐latitude ionospheric response to a sudden impulse event during northward IMF conditions [PDF]
A high‐density structure under northward interplanetary magnetic field BZ conditions is identified at the Wind and IMP 8 satellites, both in the solar wind on August 22, 1995. A compression of the magnetosphere is observed by the GOES 7 magnetometer within a few minutes of the pressure increase encountering the magnetopause.
T. Moretto +3 more
openaire +1 more source