Results 191 to 200 of about 8,192,878 (290)
Two‐dimensional CuInP2S6 nanosheets are incorporated into a P(VDF‐TrFE) matrix to induce polarization‐cooperative ferroelectric coupling. The resulting P(VDF‐TrFE)/CuInP2S6 hybrid film exhibits reinforced ferroelectric ordering and reduced coercive electric fields compared with pristine P(VDF‐TrFE).
Yeonsu Jeong +10 more
wiley +1 more source
Intrathecal EP4 Antagonist Alleviates Neuronal and Glial Activation and Hyperalgesia in a Mouse Model of Endometriosis. [PDF]
Fan P, Xiong W, Chen Y, Bai Y, Li T.
europepmc +1 more source
An ultrasound‐activatable piezoelectric hydrogel reprograms chondrocyte mitochondrial epigenetics via the mTOR/GATD3A axis, clearing damaged mitochondria and alleviating osteoarthritis progression in both mouse models and human cartilage explants. ABSTRACT The avascular nature of cartilage hinders drug delivery for osteoarthritis (OA) therapy.
Hui Zheng +9 more
wiley +1 more source
Bimetallic Steels: A Structured Review of Fabrication Routes, Material Properties, and Component Performance. [PDF]
Ding Z +5 more
europepmc +1 more source
A portable, sensorized, and controlled dexterous thumb‐enhanced glove helps stroke survivors swipe phones, twist caps, and perform other tasks. It is based on a powerful continuously, segmented origami dual chamber actuator to achieve active thumb CMC and MCP joint assistance and passively extend the IP joint.
Disheng Xie +10 more
wiley +1 more source
Targeting pain where it Cou<i>Nts:</i> the role of neurotensin signaling in pain and analgesia. [PDF]
Chapman AD +3 more
europepmc +1 more source
Conjugated poly(imide dioxime)‐based microspheres establish a radiometal coordination‐driven conformational interlocked network with ultra‐high radiostability. This platform enables low‐temperature, multi‐radionuclide labeling for SPECT/PET/MRI imaging and radionuclide therapy. Mechanistic insights from EXAFS and DFT reveal enhanced stability, while in
Xiao Xu +10 more
wiley +1 more source
Mu opioid receptors gate the locus coeruleus pain generator. [PDF]
Kuo CC +10 more
europepmc +1 more source
A flexible pressure sensor with triple‐gradient design of conductivity, modulus, and dimension in binary micro‐dome pixels is proposed. Based on precisely‐designed CNT/PDMS matrix, the device exhibits a linear sensitivity of 974.1 kPa−1 across range up to 1.8 MPa (R2 > 0.99), offering an effective strategy for potential applications in healthcare ...
Yifan Liu +9 more
wiley +1 more source

