Results 81 to 90 of about 65,219 (255)

AC Fault Ride Through in MMC-Based HVDC Systems

open access: yesIEEE Transactions on Power Delivery, 2022
VSC-HVDC systems are being increasingly employed in the power systems. The recently installed HVDC systems have a power capacity similar to traditional power plants.
S. Tavakoli   +2 more
semanticscholar   +1 more source

Multiterminal High‐Voltage Direct Current Projects: A Comprehensive Assessment and Future Prospects

open access: yesHigh Voltage, EarlyView.
ABSTRACT Multiterminal high‐voltage direct current (MT‐HVDC) systems are an important part of modern power systems, addressing the need for bulk power delivery and efficient renewable energy integration. This paper provides a comprehensive overview of recent advances in MT‐HVDC technology, including launched projects and ongoing initiatives.
Mohammad Hossein Mousavi   +3 more
wiley   +1 more source

Fault Current Limiter and Mechanical DC CB-Based Protection Against Valve-Side SPG Faults in HB-MMC Bipolar System

open access: yesIEEE Access
Valve-side single-phase-to-ground (SPG) faults are atypical yet critical for the operation of half-bridge (HB) Modular Multilevel converter (MMC) bipolar or asymmetrical monopolar systems.
Muhammad Usman   +2 more
doaj   +1 more source

Research on coordinated reactive power control strategy of hybrid-HVDC

open access: yesThe Journal of Engineering, 2019
Based on the hybrid HVDC transmission system, which is composed by line-commutated converter (LCC) in parallel with voltage source converter (VSC), a coordinated reactive power control strategy of hybrid-HVDC in both steady and transient states is ...
Ying Huang, Chunhua Li, Tao Liu
doaj   +1 more source

Impedance-compensated grid synchronisation for extending the stability range of weak grids with voltage source converters [PDF]

open access: yes, 2016
This paper demonstrates how the range of stable power transfer in weak grids with voltage source converters (VSCs) can be extended by modifying the grid synchronisation mechanism of a conventional synchronous reference frame phase locked loop (PLL).
D'Arco, Salvatore   +3 more
core   +2 more sources

The Surface Potential Restoration Algorithm of Electrostatic Capacitance Probe During On‐Line Measurement

open access: yesHigh Voltage, EarlyView.
ABSTRACT The surface charge accumulation on insulators is one of the important factors that limit the development of high‐voltage direct current (HVDC) gas insulated transmission line (GIL), and the accurate measurement of surface charge is the basis to explore its physical mechanism.
Lei Zhang   +3 more
wiley   +1 more source

Design and implementation of 30kW 200/900V LCL modular multilevel based DC/DC converter for high power applications [PDF]

open access: yes, 2016
This paper presents the design, development and testing of a 30kW, 200V/900V modular multilevel converter (MMC) based DC/DC converter prototype. An internal LCL circuit is used to provide voltage stepping and fault tolerance property.
Aboushady, A.   +3 more
core   +2 more sources

Micro Partial Discharge Characteristics of SF6 Under DC Voltage

open access: yesHigh Voltage, EarlyView.
ABSTRACT In gas‐insulated high‐voltage direct current (HVDC) devices, micro partial discharges (PD) caused by micro‐protrusions or surface roughness on conductors or enclosures may not cause immediate insulation system failure due to their weak discharge intensity.
Geng Chen   +4 more
wiley   +1 more source

Control of VSC-HVDC with electromechanical characteristics and unified primary strategy [PDF]

open access: yes, 2016
High voltage dc (HVDC) systems act as the prevailed solution for transmitting offshore wind energy to onshore main grids. Control of the voltage source converters (VSC) in HVDC systems is decisive for the performance.
Candela García, José Ignacio   +4 more
core   +1 more source

Construction and Application of Online Vibration Frequency Response Analysis Method for Converter Transformer Winding

open access: yesHigh Voltage, EarlyView.
ABSTRACT The harmonic current and vibration of a converter transformer are effective pieces of information for detecting mechanical faults in the winding. In this paper, the ratio of vibration acceleration to the current squared is defined as the vibration frequency response function (VFRF) of the winding, and then, a novel online vibration frequency ...
Shuyu Wu, Fan Zhang, Shengchang Ji
wiley   +1 more source

Home - About - Disclaimer - Privacy