Results 11 to 20 of about 178 (143)
This paper proposes a coordinated control strategy to enhance the low/high‐voltage ride‐through (L/HVRT) capability of grid‐tied micro‐grids (MGs). The novel control scheme, which is based on grid‐following concepts, contains two layers for each power ...
Reza Deihimi Kordkandi +2 more
doaj +2 more sources
An Enhanced Control Procedure for that DVR to accomplish both LVRT and HVRT in the DFIG Wind Turbine
Abstract In general, Double Fed Induction Generator DFIG-driven wind turbines are extremely sensitive to fluctuations in the grid voltage. For enhancing DFIG wind turbines, this paper proposes an improved procedure for controlling Dynamic Voltage Restorer (DVR) to simultaneously perform both Low Voltage Ride Through (LVRT) and High ...
T. Hemanth +2 more
exaly +2 more sources
Grid Connected Photo Voltaic (GCPV) system should be susceptible to grid faults and load curtailment without disconnection and supports in grid stability.
C. Nithya, J. Preetha Roselyn
doaj +2 more sources
Coordinated Droop Control and Adaptive Model Predictive Control for Enhancing HVRT and Post-Event Recovery of Large-Scale Wind Farm [PDF]
The wind turbine (WT) terminal overvoltage during grid voltage swell events may result in tripping the WT and consequently threaten the secure operation of large-scale wind farms (WFs). In this paper, an optimal coordination of droop control and adaptive model predictive control (MPC) scheme is proposed to enhance the high-voltage ride-through (HVRT ...
Qiuwei Wu, Canbing Li, Yijia Cao
exaly +2 more sources
Enhanced LVRT and HVRT Capability of Grid Tied PMSG Based Wind Energy System Using Active Disturbance Rejection Controller [PDF]
The widespread integration of wind energy poses numerous challenges, including ride-through capability issues, stability concerns, and power quality issues within the utility grid.
Sagiraju Dileep Varma +3 more
doaj +2 more sources
High voltage ride through (HVRT) control strategies for doubly-fed induction wind turbines (DFIG) have mostly focused on the rotor side converter, while the reactive power compensation capability of the grid side converter and the impact of grid side ...
Jun Deng +5 more
doaj +1 more source
Effect of two different volumes of resistance training on serum level of fibroblast growth factor-21, body fat percentage and mobility in obese elderly women [PDF]
Introduction: Fibroblast growth factor 21 (FGF21) increases lipolysis and fatty acid oxidation. The effect of different volumes of resistance training on FGF21 is not well defined.
Zeinab Fattahi +3 more
doaj +1 more source
High Voltage Ride through Strategy of Wind Farm Considering Generator Terminal Voltage Distribution
When wind power is transmitted via high-voltage direct current (HVDC), the problem of high-voltage ride-through (HVRT), caused by direct-current (DC) blocking must be seriously taken into account.
Yanhui Qin +4 more
doaj +1 more source
Enhancing the HVRT and LVRT Capabilities of DFIG-based Wind Turbine in an Islanded Microgrid [PDF]
Doubly fed induction generator (DFIG) based wind turbines are very sensitive to grid voltage variations. Therefore, low-voltage-ride-through (LVRT) and high-voltage-ride-through (HVRT) capabilities are employed to improve DFIG performance during grid faults and voltage swell events. In this paper, a superconducting magnetic energy storage (SMES) device
Safaei, A. +2 more
openaire +2 more sources
Power systems are transitioning towards a higher proportion of inverter‐based resources. This leads to the loss of synchronous generators and their associated control mechanisms. To address low inertia challenges, new international fast frequency response services are established, and renewable enabling technologies and sources are investigated to ...
Dlzar Al Kez +3 more
wiley +1 more source

