Results 11 to 20 of about 275 (163)
Enhancing the HVRT and LVRT Capabilities of DFIG-based Wind Turbine in an Islanded Microgrid [PDF]
Doubly fed induction generator (DFIG) based wind turbines are very sensitive to grid voltage variations. Therefore, low-voltage-ride-through (LVRT) and high-voltage-ride-through (HVRT) capabilities are employed to improve DFIG performance during grid faults and voltage swell events. In this paper, a superconducting magnetic energy storage (SMES) device
Safaei, A. +2 more
openaire +3 more sources
High Voltage Ride through Strategy of Wind Farm Considering Generator Terminal Voltage Distribution
When wind power is transmitted via high-voltage direct current (HVDC), the problem of high-voltage ride-through (HVRT), caused by direct-current (DC) blocking must be seriously taken into account.
Yanhui Qin +4 more
doaj +2 more sources
High voltage ride through (HVRT) control strategies for doubly-fed induction wind turbines (DFIG) have mostly focused on the rotor side converter, while the reactive power compensation capability of the grid side converter and the impact of grid side ...
Jun Deng +5 more
doaj +2 more sources
Influence of Converter DC Bus Overvoltage on Wind Turbine High Voltage Ride Through Capabilities
Off-grid occurred in a wind farm caused by converter fault during field test of the DFIG (doubly feed induction generator) high voltage ride through (HVRT) capabilities.
Guangru ZHANG +6 more
doaj +2 more sources
This paper proposes a coordinated control strategy to enhance the low/high‐voltage ride‐through (L/HVRT) capability of grid‐tied micro‐grids (MGs). The novel control scheme, which is based on grid‐following concepts, contains two layers for each power ...
Reza Deihimi Kordkandi +2 more
doaj +2 more sources
LVRT and HVRT control strategies of doubly- fed induction generator [PDF]
The Doubly Fed Induction Generator (DFIG) has a high sensitivity to the Grid Faults (GFs), which can cause many problems on the power quality and the production continuity. Actually, the grid connection requirements impose strict laws to respect to Low Voltage Ride Through (LVRT), High Voltage Ride Through (HVRT), and grid support capacities following ...
El Karkri, Yassir +3 more
core +5 more sources
Grid Connected Photo Voltaic (GCPV) system should be susceptible to grid faults and load curtailment without disconnection and supports in grid stability.
C. Nithya, J. Preetha Roselyn
doaj +3 more sources
High Voltage Crossing Strategy of Wind Farm Considering Active and Reactive Coordinated Recovery [PDF]
ObjectivesTo address the serious high voltage ride-through (HVRT) problem faced by wind farms as a result of the large voltage surge at the grid-connected point after a DC fault, a recovery mechanism of “active priority balancing - reactive power dynamic
MO Jisheng +4 more
doaj +2 more sources
Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through [PDF]
This paper presents a fast coordinated control scheme of the rotor side converter (RSC), the Direct Current (DC) chopper and the grid side converter (GSC) of doubly fed induction generator (DFIG) wind turbine generators (WTGs) to improve the low voltage ...
Yun Wang +4 more
doaj +2 more sources
Overview of HVRT technical measures for DFIG
A With the rapid increase of the proportion of double-fed induction wind turbines generator (DFIG), higher requirements are proposed for the continuous operation ability under external power grid failure. The paper first analysed the transient process of DFIG in cases of power grid voltage surge, proposed the related standard requirements for high ...
Haiyang Yu