Results 91 to 100 of about 584,755 (196)

Development of an implantable collamer lens sizing model: a retrospective study using ANTERION swept-source optical coherence tomography and a literature review

open access: yesBMC Ophthalmology, 2023
Background Optimal sizing for phakic intraocular lens (EVO-ICL with KS-AquaPort) implantation plays an important role in preventing postoperative complications.
Taein Kim   +10 more
doaj   +1 more source

Two cases of spontaneous hyphema after posterior chamber phakic intraocular lens implantation

open access: yesBMC Ophthalmology
The implantable collamer lens (ICL, STAAR Surgical Co.) surgery is popular for its effectiveness and safety, but it carries potential risks. This study presents two unreported cases of hyphema after ICL surgery, highlighting the need for prompt ...
Yang Gao, Chenxue Liu, Li Li, Qizhi Zhou
doaj   +1 more source

Clinical and Aberrometric Outcomes of a New Implantable Collamer Lens for Myopia and Presbyopia Correction in Phakic Patients

open access: yes, 2023
PURPOSE:To assess the clinical and aberrometric outcomes of a new Implantable Collamer Lens (EVO Viva ICL; STAAR Surgical) to correct moderate to high myopia and presbyopia.
Carlos Lisa   +11 more
core   +1 more source

Aqueous humor volume and Wall shear stress (WSS) on the endothelium and crystalline lens for the 14 scenarios modelled according to pupil diameter and the phakic intraocular lens (PIOL) implanted (Implantable collamer lens, ICL; Artiflex; or normal PIOL-free eye) in a closed eye (without convection).

open access: yes, 2018
Aqueous humor volume and Wall shear stress (WSS) on the endothelium and crystalline lens for the 14 scenarios modelled according to pupil diameter and the phakic intraocular lens (PIOL) implanted (Implantable collamer lens, ICL; Artiflex; or normal PIOL ...
José María Montanero (5624909)   +8 more
core   +1 more source

Implantable Collamer Lens (ICL) Sizing in Advanced Keratoconus

open access: yesDelhi Journal of Ophthalmology, 2016
A patient of advanced keratoconus underwent CXL followed by implantation of ICL. Pre-operative BCVA was 20/40 with mean refractive spherical equivalent (MRSE) of -12DS(OD) and -10DS(OS) respectively.
Ritu Arora   +4 more
doaj   +1 more source

Acute serous macular detachment with intraretinal edema after posterior-chamber phakic lens implantation:A case report

open access: yesPhotodiagnosis and Photodynamic Therapy
Introduction and importance: This report presents a case of acute serous macular detachment and intraretinal edema following Implantable Collamer Lens implantation in a 27-year-old female, emphasizing the importance of surgical timing and the cautious ...
Xue Li, Yongyi Niu
doaj   +1 more source

Innovative wireless ocular modulation patch for controlled axial length shortening

open access: yes
MedComm – Biomaterials and Applications, Volume 3, Issue 3, September 2024.
Lin Ye, Jing Zheng
wiley   +1 more source

Aqueous humor volume and Wall shear stress (WSS) produced on the endothelium and crystalline lens for the 14 scenarios modelled according to pupil diameter and the phakic intraocular lens (PIOL) implanted (Implantable collamer lens, ICL; Artiflex; or normal PIOL-free eye) in an open eye (taking into account the convection).

open access: yes, 2018
Aqueous humor volume and Wall shear stress (WSS) produced on the endothelium and crystalline lens for the 14 scenarios modelled according to pupil diameter and the phakic intraocular lens (PIOL) implanted (Implantable collamer lens, ICL; Artiflex; or ...
José María Montanero (5624909)   +8 more
core   +1 more source

A Case of Implantable Collamer Lens (ICL) with Reverse Orientation for 10 Years

open access: yes, 2021
Background. Implantable collamer lens (ICL) might rarely cause complications that warrant explantation. Here, we presented a case of inverted ICL that has undergone explantation after a 10-year duration. Case Presentation.
Raed E. Alsulami   +3 more
core   +1 more source

Home - About - Disclaimer - Privacy