Results 61 to 70 of about 584,755 (196)
Corneal Endothelial Changes Following Implantable Collamer Lens Implantation [PDF]
Background: Several studies were conducted over an extended period to rectify refractive defects. This was done by traditional methods like spectacles and contact lenses (CL) or via refractive procedures, which have come to be an acceptable option for ...
Anas Mohamed, Adel Osman, Ahmed Mohamed
doaj +1 more source
Supplemental material, sj-tif-4-ejo-10.1177_11206721221097249 for A meta-analysis of visual outcomes and optical quality after small incision lenticule extraction versus implantable collamer lens for myopia by Yu Di, Ge Cui, Ying Li and Yan Luo in ...
Yu Di (12341839) +3 more
core +1 more source
Supplemental material, sj-tif-1-ejo-10.1177_11206721221097249 for A meta-analysis of visual outcomes and optical quality after small incision lenticule extraction versus implantable collamer lens for myopia by Yu Di, Ge Cui, Ying Li and Yan Luo in ...
Yu Di (12341839) +3 more
core +1 more source
Femtosecond laser-assisted cataract surgery was performed in a patient with high myopia, who had undergone posterior chamber phakic intraocular lens surgery (Implantable Collamer Lens, ICL). During docking the machine erroneously focused the laser on the
Manas Nath, Prasanth Gireesh
doaj +1 more source
Repositioning of Vertical Implantable Phakic Contact Lens
Vertical orientation of Implantable Phakic Contact Lens. ABSTRACT Implantable phakic contact lens (IPCL) V2.0 has a special patterned hole on the leading left corner to ensure correct orientation and positioning. Incorrect orientation is an absolute indication for repositioning.
Sushank Bhalerao +4 more
wiley +1 more source
Additional file 7: Supplementary Table 1. Preoperative clinical characteristics of the study participants. Supplementary Table 2. Size and intraocular orientation of the toric implantable collamer lens. Supplementary Table 3. The number and percentage of
Jun Zhang (48506) +4 more
core +1 more source
ABSTRACT Background To investigate the predictive value of aqueous humour cytokines for axial elongation. Methods This was a prospective longitudinal observational study. 72 high myopia patients (72 eyes) who received implantable collamer lens (ICL) implantation surgery with at least 2 years of follow‐up were included.
Lihui Meng +4 more
wiley +1 more source
ICL = implantable collamer lens, CI = confidence interval, D = diopters, LogMAR = logarithm of the minimal angle of resolution, UDVA = uncorrected distance visual acuity, CDVA = corrected distance visual acuity.
Kazutaka Kamiya (284327) +4 more
core +1 more source
PurposeTo investigate the effects of ocular residual astigmatism (ORA) and target-induced astigmatism (TIA) on the efficacy of toric implantable collamer lens (TICL) with central hole for myopic astigmatism correction.MethodsRetrospective case series ...
Jing Zhao +16 more
doaj +1 more source
Purpose To compare the difference, correlation, and agreement of anterior chamber parameters measured by Pentacam and CASIA 2. Methods A total of 89 myopic patients (89 right eyes) of Beijing Tongren Hospital were included. Anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior chamber angle (ACA) were measured by Pentacam and CASIA ...
Yi Fan Li +4 more
wiley +1 more source

