Results 261 to 270 of about 2,085,793 (277)
Some of the next articles are maybe not open access.
POWERCON '98. 1998 International Conference on Power System Technology. Proceedings (Cat. No.98EX151), 2002
The lightning protection effects of power transmission lines are related to the impulse characteristics of grounding systems of transmission-line towers. The influences of several main factors on impulse grounding properties are systematically analyzed by simulation experiments according to the simulation theory in this study.
null He Jinliang +4 more
openaire +1 more source
The lightning protection effects of power transmission lines are related to the impulse characteristics of grounding systems of transmission-line towers. The influences of several main factors on impulse grounding properties are systematically analyzed by simulation experiments according to the simulation theory in this study.
null He Jinliang +4 more
openaire +1 more source
2000 IEEE ESMO - 2000 IEEE 9th International Conference on Transmission and Distribution Construction, Operation and Live-Line Maintenance Proceedings. ESMO 2000 Proceedings. Global ESMO 2000. The Power is in Your Hands (Cat. No.00CH37183), 2002
Lightning strikes may cause a rise in transmission tower potential which could produce a tower-to-phase flashover. This paper presents a computer-modeled technique applied to study this phenomena. 120 kV and 315 kV power lines have been modeled. Transmission tower potential is presented.
R. Lanoie, J. Fortin
openaire +1 more source
Lightning strikes may cause a rise in transmission tower potential which could produce a tower-to-phase flashover. This paper presents a computer-modeled technique applied to study this phenomena. 120 kV and 315 kV power lines have been modeled. Transmission tower potential is presented.
R. Lanoie, J. Fortin
openaire +1 more source
A simplified method for calculating the impulse resistance of vertical grounding rods
2002 IEEE Region 10 Conference on Computers, Communications, Control and Power Engineering. TENCOM '02. Proceedings., 2003A simplified method is proposed for calculating the impulse resistance of vertical grounding rods. The analytic formula is first derived to determine the low current resistance and then the calculation procedure is developed to estimate the impulse resistance.
openaire +1 more source
An original setup to measure grounding resistances using fast impulse currents and very short leads
Electric Power Systems Research, 2019Abstract This paper presents a method for measuring grounding resistances, which is based on the use of fast impulse current and short leads on the auxiliary measurement circuits. Usually, the conductor length of the voltage and current circuits used in grounding resistance measurements may be quite long depending on the grounding characteristics ...
A.B. Lima +5 more
openaire +1 more source
On-site measurement method of impulse grounding resistance of transmission tower grounding network
WIT Transactions on Engineering Sciences, 2015Bin Cao +6 more
openaire +1 more source
Behavior of Transient Ground Resistances of Ground Rod Subjected to Impulse Currents
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, 2019Seung-Ki Jung, Bok-Hee Lee
openaire +1 more source
Laboratory investigation of impulse characteristics of transmission tower grounding devices
IEEE Transactions on Power Delivery, 2003, Rong Zeng
exaly
Dynamic Characteristics of Ground Resistance due to Soil Ionization under Impulse Currents
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, 2018Yong-Tae Choi, Bok-Hee Lee
openaire +1 more source