Results 241 to 250 of about 3,801 (279)
Some of the next articles are maybe not open access.

Inductive current transformer accuracy of transformation for the PQ measurements

Electric Power Systems Research, 2017
Abstract Inductive current transformer made of magnetic cores with high permeability are used for accurate wideband transformation of distorted current required by the power quality (PQ) measurements. However, such solutions are often characterized by not acceptable additional secondary current distortion in condition of variation of primary current ...
Michal Kaczmarek
exaly   +2 more sources

A practical approach to evaluation of accuracy of inductive current transformer for transformation of distorted current higher harmonics

Electric Power Systems Research, 2015
Abstract In this paper the concept is discussed for evaluation of accuracy of inductive current transformer (CT) for transformation of distorted current higher harmonics. In proposed method the composite error (transformer correction factor) is determined for various operating conditions of tested CT in respect of primary currents rms value ...
Michal Kaczmarek
exaly   +2 more sources

Secondary current distortion of inductive current transformer in conditions of dips and interruptions of voltage in the power line

Electric Power Systems Research, 2016
Abstract The aim of this paper is to present results explaining the phenomenon of inductive current transformers (CT) additional secondary current distortion in condition of variation of their primary current rms value caused by dips and interruptions of the power line's voltage.
Michal Kaczmarek
exaly   +2 more sources

Research on the Electromagnetic Characteristics of an Integrated Multi-Winding Inductive Filtering Converter Transformer and Its Filter System

open access: yesElectronics (Switzerland), 2023
In this paper, the electromagnetic characteristics of a novel integrated multi-winding inductive filtering converter transformer, including two parallel-connected delta filter windings with zero impedance, are studied.
Jianying Li   +2 more
exaly   +2 more sources

Effect of temperature on the accuracy of inductive current transformers

2018 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), 2018
The paper deals with the evaluation of the accuracy variation of inductive current transformers vs. ambient temperature. There is a lack of information regarding if and how the accuracy of inductive current transformers changes with respect to temperature variations. To this purpose, in this paper a proper setup is presented and used for evaluating the
Mingotti, Alessandro   +3 more
openaire   +2 more sources

Design and Calibration of Inductive Current Transformer

Advanced Materials Research, 2013
In this paper, the design principle of inductive current transformer is introduced at first. Then an inductive current transformer is produced by applying the structure of two-stage inductive voltage divider. And finally, the error of the sample machine is given through examine test, and the suggestion for improving the machine is given based on the ...
Quan Wang, Huan Wang, Qiong Xiang
openaire   +1 more source

Operation of inductive protective current transformer in condition of distorted current transformation

2015 Modern Electric Power Systems (MEPS), 2015
In the paper the influence of conductive disturbances on transformation of fault current by inductive protective current transformers is described. Analysis of the results from laboratory studies show, that for such condition primary current up to which the current transformer will comply with the requirements for composite/ratio error is decreased ...
openaire   +1 more source

Analytic Computation of the Magnetizing Inductance of Current Instrument Transformers Under Consideration of Eddy Currents

IEEE Transactions on Magnetics, 2015
Inductive instrument transformers are widely-used to measure currents in the power grid. Harmonics currents increase due to the proliferation of nonlinear equipment in the power grid. At higher frequencies, eddy currents inside the core increase, causing a change of the electrical parameters of the current instrument transformer (CT).
C. Jaschke, P. Schegner
openaire   +1 more source

The source of the inductive current transformers metrological properties deterioration for transformation of distorted currents

Electric Power Systems Research, 2014
Abstract The aim of the paper is to present results explaining the phenomena of the inductive current transformers (CTs) metrological properties deterioration for the transformation of the distorted currents. In the article the influence of the conductive disturbances on their accuracy of transformation of the distorted signal is described.
openaire   +1 more source

Concordia Transform-Based Current Analysis for Induction Motor Diagnosis

Key Engineering Materials, 2013
This paper presents a new approach for bearing defect diagnosis in induction motor by taking advantage of three-phase stator current analysis based on Concordia transform. The current signature caused by bearing defect is firstly analyzed using an analytic model.
Jin Jiang Wang   +2 more
openaire   +1 more source

Home - About - Disclaimer - Privacy