Results 251 to 260 of about 3,801 (279)
Some of the next articles are maybe not open access.

Overvoltages caused by the interruption of small inductive transformer currents

IEEE Transactions on Power Systems, 1988
The interruption of small inductive currents can cause high overvoltages, which may overstress the dielectric strength of the equipment. Based on detailed dynamic models for the circuit breaker and the transformer, a variety of parameters which influence these overvoltages is systematically investigated by digital simulation.
openaire   +1 more source

The calibration of current transformers by means of mutual inductance: The measurement of mutual inductance and self-inductance and alternating current resistance

Proceedings of the American Institute of Electrical Engineers, 1915
Reasons are given for the selection of initial inductances as a means for calibrating current transformers, the most important of which is the wide use to which they may be put besides the calibration of current transformers. The design and manufacture of the apparatus is described, reasons being given for the choice of the form of the secondary coils ...
openaire   +1 more source

Wavelet Scattering Transform Based Induction Motor Current Signature Analysisa

2020 International Conference on Electrical Machines (ICEM), 2020
In this paper wavelet scattering transform (WST) algorithm is proposed to analyze motor current signatures and extract faults features. The algorithm overcomes the short comings of the classical techniques, which are noise sensitivity and computational complexity in features extraction.
Mesaad AlBader, Hamid A. Toliyat
openaire   +1 more source

The effect of transformer magnetizing inductance on a forward converter with current mode control

Journal of the Chinese Institute of Engineers, 2007
Abstract The small‐signal model for a forward converter with current‐mode control is derived which includes the magnetizing inductance of the main power transformer. It is found that the feedforward gain is modified by magnetizing inductance and so are the transfer functions of current loop gain, control to output and audio susceptibility.
Shen‐Yaur Chen   +2 more
openaire   +1 more source

Fourier and Wavelet Transformations for the Fault Detection of Induction Motor with Stator Current

2006
In this literature, fault detection of an induction motor is carried out using the information of stator current. After preprocessing actual data, Fourier and wavelet transforms are applied to detect characteristics under the healthy and various faulted conditions. The most reliable phase current among 3-phase currents is selected by the fuzzy entropy.
Sang-Hyuk Lee   +3 more
openaire   +1 more source

A Current-Reused VCO With Inductive-Transformer Feedback Technique

IEEE Transactions on Microwave Theory and Techniques, 2022
Cao Wan, Taotao Xu, Xiang Yi, Quan Xue
openaire   +1 more source

Evaluating Varying Burden when Inductive Current Transformers are Used for Harmonic Current Measurements

2023 IEEE 13th International Workshop on Applied Measurements for Power Systems (AMPS), 2023
Ruan Murray, Jan A. de Kock
openaire   +1 more source

Analysis of the influence of the level of signal distortion on current error and phase displacement of the inductive current transformers

2012 IEEE International Power Modulator and High Voltage Conference (IPMHVC), 2012
The aim of the paper is to present results concerning the influence of conductive disturbances on accuracy of transformation of distorted signal main harmonic through the inductive current transformers (CTs). Analysis of the results from the laboratory studies shows, that conductive disturbances in the CT primary current, in some measuring conditions ...
openaire   +1 more source

Wide Frequency Operation of the Inductive Current Transformer with Ni80Fe20 Toroidal Core

Electric Power Components and Systems, 2014
Abstract—During transformation of the power frequency currents, inductive current transformers are characterized by the values of current errors and phase displacement, which determine their accuracy class. However, current transformers catalogues do not specify these metrological parameters of transformation for the sinusoidal signals at frequencies ...
openaire   +1 more source

Design a High-efficiency Adaption Circuit for Current Transformer Induction Power

2022 5th International Conference on Power and Energy Applications (ICPEA), 2022
Li Zhiyong   +4 more
openaire   +1 more source