Results 251 to 260 of about 153,268 (299)
Domain adaptation, self-supervision, and generative augmentation enhance GNNs for breast cancer prediction. [PDF]
Qiu S, Zhao Y, Li X.
europepmc +1 more source
Induction Motor Fault Diagnosis Based on Discrete Fractional Fourier Transform of Stator Current
Feng-Chang Gu +4 more
openaire +1 more source
Active line model identification protection based on characteristic frequency phase for dual-end weakly-fed AC system. [PDF]
Hou J, Zhang Z, Fan Y, Song G, Wu X.
europepmc +1 more source
A novel high-gain isolated quasi Z-source DC-DC converter with self-balancing bipolar outputs. [PDF]
Heidarbozorg S, Radmanesh H.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Design and Calibration of Inductive Current Transformer
Advanced Materials Research, 2013In this paper, the design principle of inductive current transformer is introduced at first. Then an inductive current transformer is produced by applying the structure of two-stage inductive voltage divider. And finally, the error of the sample machine is given through examine test, and the suggestion for improving the machine is given based on the ...
Quan Wang, Huan Wang, Qiong Xiang
openaire +2 more sources
Inductive current transformer accuracy of transformation for the PQ measurements
Electric Power Systems Research, 2017Abstract Inductive current transformer made of magnetic cores with high permeability are used for accurate wideband transformation of distorted current required by the power quality (PQ) measurements. However, such solutions are often characterized by not acceptable additional secondary current distortion in condition of variation of primary current ...
M. Kaczmarek
openaire +2 more sources
2015 Modern Electric Power Systems (MEPS), 2015
In the paper the influence of conductive disturbances on transformation of fault current by inductive protective current transformers is described. Analysis of the results from laboratory studies show, that for such condition primary current up to which the current transformer will comply with the requirements for composite/ratio error is decreased ...
M. Kaczmarek
openaire +2 more sources
In the paper the influence of conductive disturbances on transformation of fault current by inductive protective current transformers is described. Analysis of the results from laboratory studies show, that for such condition primary current up to which the current transformer will comply with the requirements for composite/ratio error is decreased ...
M. Kaczmarek
openaire +2 more sources
Electric Power Systems Research, 2015
Abstract In this paper the concept is discussed for evaluation of accuracy of inductive current transformer (CT) for transformation of distorted current higher harmonics. In proposed method the composite error (transformer correction factor) is determined for various operating conditions of tested CT in respect of primary currents rms value ...
M. Kaczmarek
openaire +2 more sources
Abstract In this paper the concept is discussed for evaluation of accuracy of inductive current transformer (CT) for transformation of distorted current higher harmonics. In proposed method the composite error (transformer correction factor) is determined for various operating conditions of tested CT in respect of primary currents rms value ...
M. Kaczmarek
openaire +2 more sources
Wide Frequency Operation of the Inductive Current Transformer with Ni80Fe20 Toroidal Core
Electric Power Components and Systems, 2014Abstract—During transformation of the power frequency currents, inductive current transformers are characterized by the values of current errors and phase displacement, which determine their accuracy class. However, current transformers catalogues do not specify these metrological parameters of transformation for the sinusoidal signals at frequencies ...
M. Kaczmarek
openaire +2 more sources

