Results 61 to 70 of about 10,677,552 (246)

Investigating Breathing Dynamics of a 110 kV Oil‐Immersed Transformer Using Thermal‐Fluid‐Structure Interaction Modelling

open access: yesHigh Voltage, EarlyView.
ABSTRACT The breathing system of an oil‐immersed transformer is of vital importance for maintaining equilibrium between internal and external pressures, with any malfunction potentially disrupting the transformer's stable operation. This study develops a thermal–fluid–structure interaction (TFSI) model to simulate the breathing phenomenon in a 110 kV ...
Lujia Wang   +5 more
wiley   +1 more source

Inrush current method of transformer based on wavelet packet and neural network

open access: yesThe Journal of Engineering, 2018
The transformer is an important equipment of power system; its operation state is directly related to the security and stability of the power system. Aiming at the problem that the differential protection of power transformer has been plagued by inrush ...
Wei Wang   +5 more
doaj   +1 more source

The Analogia Entis for Reformed Theology: Retrieving Calvin's Implicit Metaphysics

open access: yesModern Theology, EarlyView.
Abstract The famous controversy between Emil Brunner and Karl Barth which led to Barth's ‘No!’ was driven by disagreements over how to read John Calvin: Barth and Brunner never agreed on whether Calvin had a doctrine of the analogy of being. This article rekindles the debate.
Silvianne Aspray
wiley   +1 more source

Study on the Time–Frequency Characteristics of Excitation Inrush Current and Its Induced Converter Transformer Vibration

open access: yesApplied Sciences
An inrush current will be generated inside a converter transformer during no-load switching on or off. The inrush current will cause severe vibration of the winding and other components of the converter transformer.
Jinzhuang Lv   +7 more
doaj   +1 more source

PRINCIPLES OF IMPLEMENTATION OF BLOCKING OF CURRENT PROTECTION OF ELECTRICAL POWER UNITS WITH TRANSFORMERS

open access: yesИзвестия высших учебных заведений и энергетических объединенний СНГ: Энергетика, 2017
Principles of implementation of current protection of elements of electric power systems with power transformers are considered. In some cases, in facilities with power transformers there could be an inrush of a magnetizing current that can cause a false
F. A. Romaniuk, A. G. Shapozhnikova
doaj   +1 more source

Controlled transition full-bridge hybrid multilevel converter with chain-links of full-bridge cells [PDF]

open access: yes, 2016
This paper proposes a controlled transition full-bridge (CTFB) hybrid multilevel converter (HMC) for medium and high voltage applications. It employs a full-bridge cell chain-link (FB-CL) between the two legs in each phase to generate multilevel bipolar ...
Adam, Grain Philip   +3 more
core   +1 more source

A Forced Union: Exploring the Consequences of India's Removal of Jammu and Kashmir's Special Status

open access: yesNations and Nationalism, EarlyView.
ABSTRACT This article adds to academic literature interested in two core questions: What happens to residents as a result of an annexation? And how do aggressor states maintain control over an annexed territory where there is a history of insurgency and mobilization for independence?
Serena Hussain
wiley   +1 more source

Improved Capacitor Voltage Feedforward for Three-Phase LCL-Type Grid-Connected Converter to Suppress Start-Up Inrush Current

open access: yesEnergies, 2017
Three-phase active damping LCL-type grid-connected converters are usually used in distributed power generation systems. However, serious inrush current will be aroused when the grid-connected converter starts, especially in rectifier mode, if no ...
Shiying Zhou   +4 more
doaj   +1 more source

Research on Inrush Current Suppression of Transformer Based on Changeable Closing Angle

open access: yesZhongguo dianli, 2022
The transformer no-load closing inrush current may cause safety problems in power grid, and the controlled switching technology with fixed target angle still has room for improvement in suppressing inrush current. A transformer inrush current suppression
Haitao LI   +5 more
doaj   +1 more source

Rectification Free from Inrush Current

open access: yesIEEJ Transactions on Industry Applications, 2002
A simple stopper of inrush current, with TRIAC, is proposed for rectification systems. Among all the switching devices only TRIAC has reverse trigger-mode that enables direct triggering by the voltage of capacitor, only after its charging up through a resistor.
openaire   +2 more sources