Results 241 to 250 of about 2,678,766 (294)
Some of the next articles are maybe not open access.
The testing of insulating materials
Materials & Design, 1989Abstract ERA Technology has devised a set of standardised tests which can be used to assess the performance of materials for different aspects of electrical low voltage switching applications. Different moulding materials were studied in conjunction with one contact materials, with the primary objective of investigating the effect of the moulding ...
D Charman, RA Simmonds
openaire +1 more source
The basis for the nondestructive testing of insulation
Electrical Engineering, 1941DIELECTRIC strength is the property of insulation that is most important to the operating power companies. The factor of safety determined by the ratio of breakdown voltage to operating voltage must be maintained. Yet this breakdown voltage cannot be measured on a finished piece of insulation.
openaire +1 more source
1988
In this chapter, attention is largely concentrated on predictive tests, aimed at determination of orders of merit, in ability to operate under contamination and at those made for purposes of research into insulator behaviour. Natural and artificial tests are covered separately.
openaire +1 more source
In this chapter, attention is largely concentrated on predictive tests, aimed at determination of orders of merit, in ability to operate under contamination and at those made for purposes of research into insulator behaviour. Natural and artificial tests are covered separately.
openaire +1 more source
Nondestructive testing of insulation
Transactions of the American Institute of Electrical Engineers, Part I: Communication and Electronics, 1953THE USER of electrical apparatus is constantly in need of information concerning the condition of the insulation. This information, at the present time, is supplied by such tests as insulation resistance, power factor, capacitance, or by more severe tests such as ?high-pot.? Unfortunately, none of these tests give a true indication of the ?health?
openaire +1 more source
The testing of porcelain insulators
Journal of the Institution of Electrical Engineers, 1929The paper discusses the technique of porcelain insulator testing. The ground covered includes the usual electrical and mechanical tests called for in the various national specifications, and also special tests of more recent origin.
openaire +1 more source
Understanding stator insulation in-process testing
2015 61st IEEE Pulp and Paper Industry Conference (PPIC), 2015Modern day manufacturing practices are focusing on maximizing production while actively pursuing ways to mitigate potential failures in their products. With rotating machinery, part of this pursuit requires qualification checkpoints during manufacturing processes. For motor stators, it is essential to perform in-process insulation testing to ensure the
Tyler R. Gaerke, David C. Hernandez
openaire +1 more source
Routine Insulation Testing of Synchronous Machines
Transactions of the American Institute of Electrical Engineers, 1951THE CONTINUOUS operation of large synchronous machines and freedom from failures in service is of vital interest to every electric utility company. One of the major causes of unpredicted and unscheduled outage is the failure of stator coil insulation.
L. F. Hunt, J. H. Vivian
openaire +1 more source
Thermal Insulation Test of RCCW with Inner Insulating Layer
Advanced Materials Research, 2010To improve the durability of external thermal insulation plate on walls, the new reinforced concrete composite wall(RCCW) with inner insulating layer of polystyrene panel was developed. The paper introduces the thermal insulation tests of the RCCWs by the protection chest method, and studies the method for eliminating the effect of heat-bridge on the ...
Shun Bo Zhao +3 more
openaire +1 more source
Power-factor testing of transformer insulation
Electrical Engineering, 1941This paper points out a method for analyzing the results obtained from dissipation-factor tests of transformer insulation. Experimental data, obtained both from transformer tests, extending over the past three years, and from tests of sample insulation, indicate a definite relation between resistance and capacitance, with varying conditions of ...
openaire +1 more source
The testing of high-voltage line insulators
Proceedings of the American Institute of Electrical Engineers, 1908The specification herein proposed as standard for the testing of high-voltage line insulators was written at the request of the chairman of the High Tension Transmission Committee in order to bring this matter before the Institute for discussion. It is not presented as representing the writer's personal opinion so much as an endeavor to harmonize ...
openaire +1 more source