Results 41 to 50 of about 159,946 (293)

Decreased cold‐sensing function of the transient receptor potential channel TRPM8 from tailed amphibians

open access: yesFEBS Open Bio, EarlyView.
Despite frogs avoiding low temperatures, examination of four salamander species revealed that none avoided cold and all possessed cold tolerance. Functional analysis of TRPM8, a cold sensor, showed that all salamander TRPM8s had lost their cold sensitivity.
Tadahiro Sawao   +3 more
wiley   +1 more source

Single-layer Pb2+ Potentiometric sensor with MoS2 Nanoflakes as Ion-to-electron transducer

open access: yesInternational Journal of Electrochemical Science, 2021
There is a growing interest in research on all-solid-state ion-selective-electrodes (ASS-ISEs), largely motivated by simplicity, fast analytical time, and low detection limit.
Lan Ju, Tao Wu, Meng-xia Xu, Nan Zhang
doaj   +1 more source

A Depolarizing Leak in Sodium Bicarbonate Cotransporter NBCe1 Causes Brain Edema

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objectives SLC4A4 encodes electrogenic sodium bicarbonate cotransporter NBCe1, prominently expressed in kidney and brain. Recessive loss‐of‐function variants in SLC4A4 cause proximal renal tubular acidosis, no brain edema. In the brain, NBCe1 is expressed by astrocytes, where it regulates pH and mediates astrocyte volume changes.
Quinty Bisseling   +16 more
wiley   +1 more source

Measurement and Modeling of Mean Ionic Activity Coefficient in Aqueous Solution Containing NaNO3 and Poly Ethylene Glycol [PDF]

open access: yesIranian Journal of Chemistry & Chemical Engineering, 2013
Potentiometric investigation on {H2O+NaNO3+PEG1500} mixtures were made at T=308.15K, using electrochemical cells with two ion-selective electrodes, (Na+ glass) as the cation ion-selective electrode against (NO3- solvent-polymer PVC) as the anion ion ...
Siamak Modarresi   +4 more
doaj  

Transformed Composite Sequences for Improved Qubit Addressing

open access: yes, 2014
Selective laser addressing of a single atom or atomic ion qubit can be improved using narrowband composite pulse sequences. We describe a Lie-algebraic technique to generalize known narrowband sequences and introduce new sequences related by dilation and
Addision, J. P.   +4 more
core   +1 more source

Duplex Stainless Steel Laser‐Surface Textured: Stability in Brine Solution

open access: yesAdvanced Engineering Materials, EarlyView.
Controlled laser‐surface treatment (LST) of duplex DSS2205 steel is performed to increase its stability in brine solution under cyclic electrochemical assays. The superior protection with respect to flat and smooth panels is attributed to the presence of FeCr2O4 as the main protective oxide layer in the LST surface, after corrosion tests. The stability
Mohammad Rezayat   +5 more
wiley   +1 more source

Integration of a sensor system into microfluidic chips [PDF]

open access: yes, 2010
There have been considerable developments in the field of potentiometric sensors in recent years mainly with respect to lowering detection limits and making sensors smaller, solid-state, robust and less expensive.[1, 2] In potentiometric measurements two
Anastasova, Salzitsa   +6 more
core  

Reduction of Oxide Inclusions During the High‐Frequency Welding of Steel via a Nonthermal Ar/H2 Plasma Jet

open access: yesAdvanced Engineering Materials, EarlyView.
High‐frequency (HF) welding of steel is limited by oxide inclusions that degrade weld quality. This study demonstrates, for the first time, the integration of a nonthermal Ar/H2 dielectric barrier discharge (DBD) plasma jet into HF welding. Local plasma treatment provides effective shielding and in‐situ oxide reduction, resulting in markedly fewer and ...
Viktor Udachin   +4 more
wiley   +1 more source

THIOCYANATE ION-SELECTIVE PVC MEMBRANE ELECTRODE [PDF]

open access: yesChemistry Journal of Moldova: General, Industrial and Ecological Chemistry, 2010
A potentiometric selective sensor based on trinuclear chromium(III) complex as a novel ionophore for the thiocyanateselective electrode is reported. The sensor displays a near Nernstian slope of 57 ± 2 mV per decade, over a wide pH range 3 - 11.
Mihail Revenco   +2 more
doaj  

the Potentiometric determination of fluoride in various brands of toothpaste

open access: yesZanco Journal of Pure and Applied Sciences, 2022
The potentiometric analysis of the fluoride content (as F-ion) in toothpaste suspension with an ion-selective fluoride electrode is simple, reliable and inexpensive.
ahmad barzingi
doaj  

Home - About - Disclaimer - Privacy