Results 191 to 200 of about 87,073,951 (324)
C. Rivière +6 more
semanticscholar +1 more source
Vision begins not with images but with change: the retina fires only when something moves, handing the brain a stream of spikes. A neuromorphic imaging system adopts the same strategy—an event sensor that sees like the retina, a spiking network that thinks like the brain—to track and reconstruct fully randomly moving targets through tissue (phantom ...
Ning Zhang, Arto Nurmikko
wiley +1 more source
Analysis and generation of motion profiles from positive and negative human actions. [PDF]
Russo A +3 more
europepmc +1 more source
Given that PEEK chest wall implants induce shear force at the soft tissue‐implant interface due to respiratory motion in the early in vivo post‐implantation stage. We confirmed that this mechanical stimulus triggers the PIEZO1/ITGB1/YAP1 signalling axis in L929 and the STAT6/p‐STAT6 pathway in RAW264.7, which in turn mediates adhesion and migration of ...
Rou Huang +14 more
wiley +1 more source
Kinematic Alignment in TKA Using the Contralateral Healthy Knee as Reference: A Combined Finite Element and Clinical Analysis. [PDF]
Kong L +6 more
europepmc +1 more source
Origami has inspired numerous soft deployable mechanisms for safe human‐robot interaction, while its intrinsic kinematic instability at arbitrary configurations limited their practical robotic application. This work presents a 3D printed meter‐scale origami robotic actuator capable of load‐bearing deformation through creaseline stiffness modulation.
Sung Yol Yu +5 more
wiley +1 more source
Inverse Design of Pre‐Strain via a Predictive Electromechanical Model for Enhanced Strain Sensing
An analytical electromechanical model rooted in microcrack evolution mechanics is globally calibrated from only eight pre‐strain datasets, enabling prediction of the complete sensing response at untested pre‐strain values within the calibrated design space (R2 > 0.99).
Jia‐Chen Shang +10 more
wiley +1 more source
Revision of Unicompartmental Knee Arthroplasty to Total Knee Arthroplasty Using the CORI<sup>TM</sup> Imageless System: A Step-By-Step Surgical Technique. [PDF]
Croitor D +5 more
europepmc +1 more source
MOF‐Derived Cu‐TiO2/Alginate Micromotors for Buoyancy‐Regulated 3D Motion
In this work, cyanobacteria‐inspired sodium alginate (SA)/Cu‐TiO2/Fe3O4 hydrogel micromotors generate and encapsulate O2 microvesicles upon light irradiation, enabling buoyancy‐mediated Z‐axis upward migration and surface enrichment at the light‐exposed water‐air surface.
Wei Zou +7 more
wiley +1 more source
Hand Dominance Influences Motor Recovery Trajectories Following Stroke: A Longitudinal Study. [PDF]
Gutterman J +10 more
europepmc +1 more source

