An Arthroscopic Technique for Hybrid Double-Row Repair Using a Cancellous Screw and Washer for Enhanced Lateral-Row Fixation in Osteoporotic Massive Rotator Cuff Tears With Long-Head Biceps Augmentation. [PDF]
Chawanpaiboon P +4 more
europepmc +1 more source
Integration of Low‐Voltage Nanoscale MoS2 Memristors on CMOS Microchips
This article presents the first monolithic integration of nanoscale MoS2‐based memristors into the back‐end‐of‐line of foundry‐fabricated CMOS microchips in a one‐transistor‐one‐resistor (1T1R) architecture. The MoS2‐based 1T1R cells exhibit forming‐free, nonvolatile resistive switching with ultra‐low operating voltages, low cycle‐to‐cycle variability ...
Jimin Lee +16 more
wiley +1 more source
The Direct Medial and Lateral Inferior Horizontal Portals of the Knee: A Modified Arthroscopic Approach for Anterior Horn Horizontal Tears. [PDF]
Luo W, Guo D, Liu Z, Liu X.
europepmc +1 more source
Optoelectronic synaptic devices based on solution‐processed molecular telluride GST‐225 phase‐change inks are demonstrated for three‐factor learning. A global optical signal broadcast through a silicon waveguide induces non‐volatile conductance updates exclusively in locally electrically flagged memristors.
Kevin Portner +14 more
wiley +1 more source
ABSTRACT Electronic waste has emerged as a major environmental challenge, driven by the massive consumption and a limited lifetime of modern electronic devices, stimulating the development of sustainable electronics. Here, an all‐biomaterial gelatin‐choline‐citric acid ([Ch][CA]) ionogel is developed as an active binder to realize self‐sintered ...
Lin Guo +10 more
wiley +1 more source
Comparative analysis of endoscopic endonasal far-medial, far-lateral transcondylar and combined approaches to the foramen magnum region: volumetric analysis and quantitative insights on surgical exposure and maneuverability. [PDF]
Blue R +7 more
europepmc +1 more source
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang +7 more
wiley +1 more source
Fully additive vertical organic electrochemical transistors (vOECTs) with channel‐length of 226 nm on a 50 µm compostable substrate achieve >106 current modulation and ∼36 mS transconductance. Ion‐selective integration enables 1.1 mA dec−1 sensitivity and 36 µm detection limit, highlighting a scalable platform for sustainable electronics and ...
Giulia Frusconi +3 more
wiley +1 more source
Application of Ultrasonographic Evaluation in Conservative Treatment for Femoral Fracture During Cesarean Section: A Case Report. [PDF]
Sakamoto Y +3 more
europepmc +1 more source
Omnipolar Magnetic Field Detection by Superlattice‐Based Hall Sensor
Magnetic‐field‐induced electronic switching is demonstrated in unit‐cell‐engineered La0.7Sr0.3MnO3–BiFeO3 superlattices. Distinct substrate terminations modify magnetic and transport properties. Hall resistance measurements show omnipolar, hysteretic anomalous Hall switching above the Curie temperature, arising from Fe─Mn interfacial exchange, enabling
Mark Huijben +6 more
wiley +1 more source

