Results 71 to 80 of about 29,003 (304)

Frequency Dependent Model of Leakage Inductance for Magnetic Components

open access: yesAdvanced Electromagnetics, 2012
Theoretical methods for the calculation of winding losses with respect to frequency have been well documented, but the variation in leakage inductance of magnetic components due to frequency has been less well addressed. In this paper Dowell’s well-known
P. R. Wilson, R. Wilcock
doaj   +1 more source

Adaptable Tile‐Based Pneumatic Origami through Structurally Coupled Localized Actuation

open access: yesAdvanced Engineering Materials, EarlyView.
This article presents tile‐based pneumatic origami structures with rigid tiles and flexible fabric creases, achieving adaptable properties including morphing shape, selective multistability, and tunable stiffness. Independently pressurized folding bladders at each crease enable structurally coupled localized actuation of origami structures.
Tiantian Li, Jonathan Luntz, Diann Brei
wiley   +1 more source

Analysis on Leakage Inductance and Winding Resistance of High Frequency Toroidal Transformer with Interleaved Winding and Litz Wire

open access: yesJurnal EECCIS (Electrics, Electronics, Communications, Controls, Informatics, Systems)
High-frequency transformers offered numerous advantages but also presented several challenges. As frequency increased, the dimensions of the transformer decreased, making parasitic parameters more dominant and unavoidable.
Dody Yunus Putra Siregar   +2 more
doaj   +1 more source

Influence of magnetic saturation on induction motor model selection [PDF]

open access: yes, 2006
Effects of magnetic saturation on various equivalent circuit models of an induction motor are studied. The parameters of 2.2-kW and 37-kW motors with closed rotor slots are analyzed using finite element computations.
Hinkkanen, Marko   +2 more
core  

Line-start permanent-magnet motor single-phase steady-state performance analysis [PDF]

open access: yes, 2003
This paper describes an efficient calculating procedure for the steady-state operation of a single-phase line-start capacitor-run permanent-magnet motor.
Cossar, C.   +6 more
core   +1 more source

Matrix Transformer with Integrated Leakage Inductance

open access: yes2025 7th Global Power, Energy and Communication Conference (GPECOM)
Due to the rapid growth of electric aircraft, the need for high-power converters with significant weight reduction has increased. This article proposes a matrix transformer as a solution for isolated DC/DC converters (270V/28V). The matrix transformer enable the integration of leakage inductance through a five-leg magnetic core geometry.
Mensouri, Sanae   +2 more
openaire   +2 more sources

Effects of Carbon Nanoparticles on Triboelectro‐Induced Surface Defects

open access: yesAdvanced Engineering Materials, EarlyView.
Carbon nanoparticles added to grease modify the electrocontact behavior. The synergy of particle concentration and electric current dominates the surface damage of metals in contact. Electrical surface damage caused by current leakage is a critical challenge in high‐performance applications such as electric vehicle (EV) drivetrains and wind turbine ...
Mohsen Tajedini   +6 more
wiley   +1 more source

High Step-Up Interleaved Converter Mixed With Magnetic Coupling and Voltage Lift

open access: yesIEEE Access, 2020
In this paper, a non-isolated high step-up interleaved DC-DC converter for distributed generation applications such as solar cells and fuel cells. The proposed converter mixes the benefits of magnetic coupling, voltage multiplier, and voltage lift ...
Sang-Wha Seo, Dong-Kuk Lim, Han Ho Choi
doaj   +1 more source

Overvoltage protection network [PDF]

open access: yes, 1974
Electrical equipment to be protected from overvoltage is connected with a possible source of overvoltage via an input conductor. A fuse is connected in series with the input conductor.
Cambra, J. M.
core   +1 more source

A new behavioural model for performance evaluation of common mode chokes [PDF]

open access: yes, 2007
A galvanically isolated three-phase AC/AC converter with a high-frequency AC-link has been analyzed from an EMC point of view. This is a special configuration because of a large number of switches, a high frequency transformer, and a fourwire output. The
Bergsma, H.   +5 more
core   +4 more sources

Home - About - Disclaimer - Privacy