Results 61 to 70 of about 705 (160)
Properties of different thin-layer LiF:Mg,Cu,P TL detectors for beta dosimetry
Dosimetric properties of two different types of thin TL detectors, designed to measure personal doses at a depth of 7 mg.cm(-2) in tissue, have been compared. At Riso National Laboratory detectors were prepared by fixing LiF:Mg,Cu,P GR-200 thin detectors
Bilski, P. +3 more
core
The shape of composite peak 5 in the glow curve of LiF:Mg,Ti (TLD-100), specifically, the ratio of the intensity of peak 5a to peak 5, is employed to separately estimate the gamma and alpha particle components in a mixed radiation field.
Sibony, D. +4 more
core +1 more source
TEZ9767Tez (Yüksek Lisans) -- Çukurova Üniversitesi, Adana, 2012.Kaynakça (s. 109-118) var.xv, 119 s. : res. (bzs. rnk.), tablo ; 29 cm.Bu çalışmada tıpta kullanılan dozimetrelerden LiF:Mg,Ti (TLD-100) termolüminesans dozimetre ve XR-QA2 model ...
Gürlek, Ali Kazim
core
Purpose: Experimental radiation dosimetry with thermoluminescent dosimeters (TLDs), calibrated in a (60)Co or megavoltage (MV) photon beam, is recommended by AAPM TG-43U1for verification of Monte Carlo calculated absorbed doses around brachytherapy ...
Alm Carlsson, Gudrun, +4 more
core +1 more source
Study of LiF:Mg,Cu,P TL detectors for individual monitoring for weakly penetrating radiations
The results are described of a study of three commercially available LiF:Mg,Cu,P TL materials aiming at using this phosphor for individual monitoring for weakly penetrating radiations.
Christensen, P.
core
A kinetic model for the thermoluminescent high dose response of LiF:Mg, Cu,P (MCP-N)
This contribution describes a kinetic model attempting to reproduce the response of the thermoluminescent material LiF:Mg,Cu,P when it is irradiated to absorbed dose values in the kGy range.
CORRECHER DELGADO, VIRGILIO +2 more
core
Study of the response reduction of LiF:Mg, Ti dosimeter for high dose dosimetry
A single crystal and 5 polycrystalline samples of LiF:Mg, Ti and their pellets were prepared and investigated so as to apply thermoluminescence high gamma dose dosimetry.
F. Mardashti +3 more
core +1 more source
Response characteristics of LiF:Mg, Cu, P TL detectors in boron neutron capture therapy dosimetry
Systematic tests were made in order to determine the neutron and gamma response characteristics of LiF:Mg,Cu,P detectors MCP-7s (TLD Niewiadomski) for use in boron neutron capture therapy (BNCT).
Auterinen, Iiro +4 more
core +1 more source
Síntesis y Caracterización Estructural de LiF:Mg, Ti
Se sintetiza Fluoruro de Litio dopado con magnesio y Titanio (LiF:Mg,Ti) por el método de recristalización y se determinan propiedades morfológicas y estructurales para analizar su viabilidad para su uso como detector de radiación ionizante.
Lozano Rojas, I. +2 more
core
ANOMALOUS BEHAVIOR OF LiF:Mg,Cu,P (TLD100H) IRRADIATED WITH ELECTRON BEAMS
Thermoluminescent dosimeters of LiF:Mg,Cu,P (TLD100H) were exposed to 60Co γ-ray, protons, high energy electrons and the glow curves were analyzed. We observed an unusual behavior of the TL response of dosimeters to 7 and 14 MeV electron beam.
BRAI, Maria +3 more
core +1 more source

