Results 71 to 80 of about 108,533 (297)

Tunable Perpendicular Magnetoresistive Sensor Driven by Shape and Substrate Induced Magnetic Anisotropy

open access: yesAdvanced Sensor Research, 2023
Control of magnetization reversal processes is a key issue for the implementation of magnetic materials in technological applications. The modulation of shape magnetic anisotropy in nanowire structures with a high aspect ratio is an efficient way to tune
Aleix Barrera   +10 more
doaj   +1 more source

CCDC80 suppresses high‐grade serous ovarian cancer migration via negative regulation of B7‐H3

open access: yesMolecular Oncology, EarlyView.
PAX8 is a lineage‐specific master regulator of transcription in high‐grade serous ovarian cancer (HGSC) progression. We show for the first time that PAX8 facilitates proliferation and metastasis by repressing the cell autonomous tumor suppressor CCDC80 and inducing B7‐H3 expression.
Aya Saleh   +12 more
wiley   +1 more source

Heterozygous loss‐of‐function alleles associate the conserved 3′‐5′ exoribonuclease EXOSC10 with hypersensitivity to the anticancer drug 5‐fluorouracil

open access: yesMolecular Oncology, EarlyView.
EXOSC10, an essential nuclear RNA exosome‐associated 3′‐5′ exoribonuclease, is inhibited by the anticancer drug 5‐fluorouracil (5‐FU), and EXOSC10 depletion increases 5‐FU sensitivity. The colon‐cancer variant EXOSC10S402T, located in a proteolysis motif, is stable and nuclear but nonfunctional in vivo.
Radhika Sain   +10 more
wiley   +1 more source

Longitudinal circulating tumor DNA profiling in patients with advanced endometrial cancer using an off‐the‐shelf targeted NGS panel

open access: yesMolecular Oncology, EarlyView.
Intratumour heterogeneity complicates precision management of advanced endometrial cancer. Circulating tumor DNA (ctDNA) offers a minimally invasive strategy to capture tumor evolution and therapeutic resistance. Here, we compare tumor‐agnostic NGS with tumor‐informed ddPCR, outlining their relative sensitivity, concordance, and clinical implications ...
Carlos Casas‐Arozamena   +15 more
wiley   +1 more source

Clusters of Spin Valve Sensors in 3D Magnetic Field of a Label

open access: yes, 2021
Magnetic field sensors based on the giant magnetoresistance (GMR) effect have a number of practical current and future applications. We report on a modeling of the magnetoresistive response of moving spin-valve (SV) GMR sensors combined in certain ...
Mikhail G. Kozin   +5 more
core   +1 more source

Advancement in scanning magnetic microscopy utilizing high-sensitivity room-temperature TMR sensors for geological applications

open access: yesEarth, Planets and Space
Scanning magnetic microscopes enable high-sensitivity mapping of magnetic fields in thin geological sections, facilitating submillimeter- to submicrometer-scale studies of paleomagnetism and rock magnetism. Magnetic fields of geological samples have been
Hirokuni Oda   +8 more
doaj   +1 more source

Magnetic method of rail track joint gaps automated measurement

open access: yesВестник Научно-исследовательского института железнодорожного транспорта
Introduction. Methods of automatic measurement of rail track joint gaps are not accurate enough or require costly equipment and sensors. This is why joint gaps are still monitored manually in many cases.
A. A. Markov   +2 more
doaj   +1 more source

Ferromagnetic Mass Localization in Check Point Configuration Using a Levenberg Marquardt Algorithm

open access: yesSensors, 2009
A detection and tracking algorithm for ferromagnetic objects based on a two stage Levenberg Marquardt Algorithm (LMA) is presented. The procedure is applied to localization and magnetic moment estimation of ferromagnetic objects moving in the vicinity of
Tsuriel Ram-Cohen   +3 more
doaj   +1 more source

Circulating tumor cell viability during and after radiotherapy mirrors treatment response in cancer patients

open access: yesMolecular Oncology, EarlyView.
Radiotherapy (RT) response depends on the DNA repair capacity of tumor and host cells. We show that circulating tumor cell (CTC) counts and apoptosis rates before and after RT predict treatment response and outcome, which can be accessed via easily accessible liquid biopsy approaches. Created in BioRender. Wikman, H.
Yvonne Goy   +10 more
wiley   +1 more source

On the vertigo due to static magnetic fields. [PDF]

open access: yes, 2013
Vertigo is sometimes experienced in and around MRI scanners. Mechanisms involving stimulation of the vestibular system by movement in magnetic fields or magnetic field spatial gradients have been proposed.
Antunes, Andre   +14 more
core   +1 more source

Home - About - Disclaimer - Privacy