Results 81 to 90 of about 544,111 (317)

Modulation of Homer1 EVH1 domain internal dynamics by putative autism‐associated mutations

open access: yesFEBS Letters, EarlyView.
The putative autism‐associated M65I and S97L variants of the EVH1 domain of the postsynaptic scaffold protein Homer1 do not exhibit substantial changes in their overall structure or partner binding. Both of them, but especially the M65I variant, show altered internal dynamics relative to the wild‐type domain on the μs‐ms timescale, indicated by the ...
Fanni Farkas   +6 more
wiley   +1 more source

Establish electromyography measurement and control technique by virtual instrument

open access: yes, 2012
[[abstract]]In this research, electromyography measurement and control technique are designed and constructed. The structure of virtual instrument built by software part, Labview hardware part, DAQ card and some external circuits is applied in the ...
Yao, Kai-chao; Huang, W.-T. ; Chiang, J.-S
core  

The smartphone as an instrument for blood pressure measurement [PDF]

open access: yes, 2017
Introduction: Number of population suffering from hypertension is increasing. So that, monitoring of this phenomenon should concentrate attention of medical industry, and receive high priority. One of the recommended procedure in hypertension treatment,
Tomasz Klepko   +4 more
core   +1 more source

Dress Code Monitoring Method in Industrial Scene Based on Improved YOLOv8n and DeepSORT

open access: yesSensors
Deep learning-based object detection has become a powerful tool in dress code monitoring. However, even state-of-the-art detection models inevitably suffer from false alarms or missed detections, especially when handling small targets such as hats and ...
Jiadong Zou   +4 more
doaj   +1 more source

A new pipeline inclination measurement method using spherical inner detector

open access: yesDianzi Jishu Yingyong, 2018
Spherical inner detector has a large error in measuring pipeline inclination for its difficulty to calibrate pipeline magnetic shield model. Against to this drawback, a new method of measuring pipeline inclination was proposed without using pipeline ...
Su Zhichao   +5 more
doaj   +1 more source

Electron transfer between complexes III and IV in S. cerevisiae mitochondrial membranes

open access: yesFEBS Letters, EarlyView.
Mitochondrial oxidative phosphorylation in S. cerevisiae mitoplasts is limited by complex IV catalytic capacity, rather than two‐dimensional cytochrome c diffusion. At physiological cytochrome c : supercomplex ratios at salinity equivalent to that of 20 mm monovalent salt, activity is maximized, indicating that this low ionic strength accurately mimics
Ana Paula Lobez   +2 more
wiley   +1 more source

Electro-ocular Measurement and Control Technique by Integrating Virtual Instrument

open access: yes, 2012
[[abstract]]In this research, electro-ocular control technique is designed and constructed. The structure of virtual instrument built by software part, LabviewBhardware part, DAQ card and some external circuits is applied in the development process. This
Yao, Kai-chao; Huang, Wei-tzer
core  

EDPNet (Efficient DB and PARSeq Network): A Robust Framework for Online Digital Meter Detection and Recognition Under Challenging Scenarios

open access: yesSensors
Challenges such as perspective distortion, irregular reading regions, and complex backgrounds in natural scenes hinder the accuracy and efficiency of automatic meter reading systems.
Songwen Guan   +4 more
doaj   +1 more source

Salmonella lipopolysaccharide‐containing supported lipid bilayers as platforms to study bacteriophage interactions

open access: yesFEBS Letters, EarlyView.
We present robust protocols for the preparation of supported lipid bilayers (SLBs) incorporating either Salmonella smooth LPS or outer membrane vesicles (OMVs). We use a combination of quartz crystal microbalance with dissipation (QCM‐D) and fluorescence microscopy to both characterize the SLBs of various compositions and to probe their interactions ...
Hudson P. Pace   +6 more
wiley   +1 more source

Pre-validation methods for developing a patient reported outcome instrument [PDF]

open access: yes, 2011
Background: Measures that reflect patients' assessment of their health are of increasing importance as outcome measures in randomised controlled trials.
Ramsay, Craig R   +47 more
core   +1 more source

Home - About - Disclaimer - Privacy