Results 101 to 110 of about 395,154 (260)
Environmental issues associated with the aviation industry are getting more attention as air traffic increases. Stringent standards are imposed for fuel consumption and pollution emissions for next-generation aircraft.
Muhammad Junaid +5 more
doaj +1 more source
Detection of Failures in Metal Oxide Surge Arresters Using Frequency Response Analysis. [PDF]
Zacarias TG +9 more
europepmc +1 more source
Origin of solid-state activated sintering in BiO₂₃-doped ZnO. [PDF]
Thesis (S.M.)--Massachusetts Institute of Technology, Dept.
Luo, Jian, 1971-
core
This study presents an experimental evaluation of surge protection performance of a LED road luminaire subjected to standardized 8/ $20\mu $ s impulse stress.
Vasilios P. Androvitsaneas
doaj +1 more source
The development of hybrid surge protection circuit with effect of adding a filter [PDF]
Surge protective device is a part of internal lightning protection and it crucially to divert the certain amount of surges to the ground before the protected load able to handle. Therefore, this paper studying the enhancement of SPD through the effect of
Ab Kadir, Mohd Zainal Abidin +2 more
core
First-principles study of a tilt grain-boundary in rutile [PDF]
[[abstract]]The atomic and electronic structure of a tilt grain boundary in rutile TiO2 has been calculated in an ab initio manner. The method employs a plane-wave basis set and optimized pseudopotentials and is carried out within the local-density ...
D. M. Ceperley +26 more
core +1 more source
Metal oxide varistor (MOV) is a nonlinear resistive element whose resistance decreases rapidly when the applied voltage exceeds a threshold value. A dc solid-state circuit breaker (SSCB) uses MOVs or MOV with resistor-capacitor-diode (RCD) snubber ...
Seong Jin Lim +3 more
doaj +1 more source
Effects of Dopants and Processing Parameters on the Properties of ZnO-V2O5-Based Varistors Prepared by Powder Metallurgy: A Review. [PDF]
Lungu MV.
europepmc +1 more source
STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES [PDF]
Abstrak Electric energy has been transmiting from power station to end user with transmission and distribution lines. Lightning strokes are problems that occure in transmission and distribution lines and make them fault when the electric energy were ...
Liliyana NS, Liliyana NS +2 more
core
Electromigration Degradation Model of Metal Oxide Varistor Structures
Наведено результати моделювання впливу міграції іонів у напівпровідникових кристалітах оксиду цинку при тривалому протіканні робочого електричного струму на вольт-амперні характеристики варисторних структур і визначення умов та параметрів, придатних для контролю процесу їхньої незворотної деградації.
Ivanchenko, A.V., Tonkoshkur, A.S.
openaire +1 more source

