Results 121 to 130 of about 475,480 (267)

串联补偿装置用MOV工况分析及其关键技术的研究

open access: yesGaoya dianqi, 2014
结合串联补偿装置的工作原理,仔细分析了金属氧化物限压器(metal oxide varistor,MOV)的工况,比较了TCSC与FSC不同构成的串联补偿装置中MOV的特点,对MOV的过电压保护和控制措施进行了较深入的讨论、总结。对设计MOV的关键技术——保护水平、能量耐受和工频电压稳定性、电流分布、特殊的短路电流释放能力等进行了深入研究。笔者根据国内某一500 kV交流电力系统串补工程的招标技术要求,设计了复合外套和瓷外套不同结构的MOV,产品通过了中国电力科学研究院的型式试验,满足工程需要。
赵冬一   +5 more
doaj  

Lightning Surge Immunity of LED Road Luminaires: A Comparative Study of Hybrid SPD, EMI Filter, and TVS-Diode Protection Strategies

open access: yesIEEE Access
This study presents an experimental evaluation of surge protection performance of a LED road luminaire subjected to standardized 8/ $20\mu $ s impulse stress.
Vasilios P. Androvitsaneas
doaj   +1 more source

Comparison of Surge Voltage Reduction and Economic Efficiency of DC SSCBs According to MOV and RCD Snubber Combination

open access: yesIEEE Open Journal of the Industrial Electronics Society
Metal oxide varistor (MOV) is a nonlinear resistive element whose resistance decreases rapidly when the applied voltage exceeds a threshold value. A dc solid-state circuit breaker (SSCB) uses MOVs or MOV with resistor-capacitor-diode (RCD) snubber ...
Seong Jin Lim   +3 more
doaj   +1 more source

STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES [PDF]

open access: yes, 2009
Abstrak Electric energy has been transmiting from power station to end user with transmission and distribution lines. Lightning strokes are problems that occure in transmission and distribution lines and make them fault when the electric energy were ...
Liliyana NS, Liliyana NS   +2 more
core  

Test Facility and Preliminary Performance of a 100 kW Class MPD Thruster [PDF]

open access: yes
A 260 kW magnetoplasmadynamic (MPD) thruster test facility was assembled and used to characterize thrusters at power levels up to 130 kW using argon and helium propellants.
Haag, Thomas W.   +4 more
core   +1 more source

A voltage-clamped bidirectional fault current limiter based on a three-winding coupled inductor for DC power grids

open access: yesInternational Journal of Electrical Power & Energy Systems
The DC fault is a serious challenge to voltage-source-converter-based HVDC (VSC-HVDC) systems, and the fault current limiter (FCL) is one of the key measures to solve the DC fault and reduce the capacity of the DC circuit breaker.
Ziao Yuan   +4 more
doaj   +1 more source

Degradación y recuperación de varistores de ZnO

open access: yesBoletín de la Sociedad Española de Cerámica y Vidrio, 2006
In the present work it was studied the main aspect that influences on degradation and physical-chemical properties at grainboundary region of metal oxide varistors and its consequences on microstructure and nonohmic electric properties.
Ramírez, M. A.   +3 more
doaj  

The development of hybrid surge protection circuit with effect of adding a filter [PDF]

open access: yes, 2011
Surge protective device is a part of internal lightning protection and it crucially to divert the certain amount of surges to the ground before the protected load able to handle. Therefore, this paper studying the enhancement of SPD through the effect of
Ab Kadir, Mohd Zainal Abidin   +2 more
core  

Home - About - Disclaimer - Privacy