Results 121 to 130 of about 475,480 (267)
结合串联补偿装置的工作原理,仔细分析了金属氧化物限压器(metal oxide varistor,MOV)的工况,比较了TCSC与FSC不同构成的串联补偿装置中MOV的特点,对MOV的过电压保护和控制措施进行了较深入的讨论、总结。对设计MOV的关键技术——保护水平、能量耐受和工频电压稳定性、电流分布、特殊的短路电流释放能力等进行了深入研究。笔者根据国内某一500 kV交流电力系统串补工程的招标技术要求,设计了复合外套和瓷外套不同结构的MOV,产品通过了中国电力科学研究院的型式试验,满足工程需要。
赵冬一 +5 more
doaj
This study presents an experimental evaluation of surge protection performance of a LED road luminaire subjected to standardized 8/ $20\mu $ s impulse stress.
Vasilios P. Androvitsaneas
doaj +1 more source
Metal oxide varistor (MOV) is a nonlinear resistive element whose resistance decreases rapidly when the applied voltage exceeds a threshold value. A dc solid-state circuit breaker (SSCB) uses MOVs or MOV with resistor-capacitor-diode (RCD) snubber ...
Seong Jin Lim +3 more
doaj +1 more source
STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES [PDF]
Abstrak Electric energy has been transmiting from power station to end user with transmission and distribution lines. Lightning strokes are problems that occure in transmission and distribution lines and make them fault when the electric energy were ...
Liliyana NS, Liliyana NS +2 more
core
Test Facility and Preliminary Performance of a 100 kW Class MPD Thruster [PDF]
A 260 kW magnetoplasmadynamic (MPD) thruster test facility was assembled and used to characterize thrusters at power levels up to 130 kW using argon and helium propellants.
Haag, Thomas W. +4 more
core +1 more source
The DC fault is a serious challenge to voltage-source-converter-based HVDC (VSC-HVDC) systems, and the fault current limiter (FCL) is one of the key measures to solve the DC fault and reduce the capacity of the DC circuit breaker.
Ziao Yuan +4 more
doaj +1 more source
Recovery of Antimony: A Laboratory Study on the Thermal Decomposition and Carbothermal Reduction of Sb(III), Bi(III), Zn(II) Oxides, and Antimony Compounds from Metal Oxide Varistors [PDF]
Toni Karlsson +2 more
openalex +1 more source
Degradación y recuperación de varistores de ZnO
In the present work it was studied the main aspect that influences on degradation and physical-chemical properties at grainboundary region of metal oxide varistors and its consequences on microstructure and nonohmic electric properties.
Ramírez, M. A. +3 more
doaj
The development of hybrid surge protection circuit with effect of adding a filter [PDF]
Surge protective device is a part of internal lightning protection and it crucially to divert the certain amount of surges to the ground before the protected load able to handle. Therefore, this paper studying the enhancement of SPD through the effect of
Ab Kadir, Mohd Zainal Abidin +2 more
core
Effects of Dopants and Processing Parameters on the Properties of ZnO-V2O5-Based Varistors Prepared by Powder Metallurgy: A Review. [PDF]
Lungu MV.