Results 101 to 110 of about 2,235 (252)
STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES
Electric energy has been transmiting from power station to end user with transmission and distribution lines.Lightning strokes are problems that occure in transmission and distribution lines and make them fault when theelectric energy were transmited ...
Agung Warsito +2 more
doaj
Dielectric Loss and Electrical Conductivity Behaviors of Epoxy Composites Containing Semiconducting ZnO Varistor Particles. [PDF]
Lei L, Chen C, Nie H, Wu X, Tan DQ.
europepmc +1 more source
Rural Facility Electric Power Quality Enhancement [PDF]
Electric power disturbances are known to be more prevalent in small, isolated power systems than in larger interconnected grids which service most of the United States. This fact has given rise to a growing concern about the relative merits of different
Aspnes, J.D. +3 more
core
First-principles study of a tilt grain-boundary in rutile [PDF]
[[abstract]]The atomic and electronic structure of a tilt grain boundary in rutile TiO2 has been calculated in an ab initio manner. The method employs a plane-wave basis set and optimized pseudopotentials and is carried out within the local-density ...
D. M. Ceperley +26 more
core +1 more source
Environmental issues associated with the aviation industry are getting more attention as air traffic increases. Stringent standards are imposed for fuel consumption and pollution emissions for next-generation aircraft.
Muhammad Junaid +5 more
doaj +1 more source
结合串联补偿装置的工作原理,仔细分析了金属氧化物限压器(metal oxide varistor,MOV)的工况,比较了TCSC与FSC不同构成的串联补偿装置中MOV的特点,对MOV的过电压保护和控制措施进行了较深入的讨论、总结。对设计MOV的关键技术——保护水平、能量耐受和工频电压稳定性、电流分布、特殊的短路电流释放能力等进行了深入研究。笔者根据国内某一500 kV交流电力系统串补工程的招标技术要求,设计了复合外套和瓷外套不同结构的MOV,产品通过了中国电力科学研究院的型式试验,满足工程需要。
赵冬一 +5 more
doaj
This study presents an experimental evaluation of surge protection performance of a LED road luminaire subjected to standardized 8/ $20\mu $ s impulse stress.
Vasilios P. Androvitsaneas
doaj +1 more source
Detection of Failures in Metal Oxide Surge Arresters Using Frequency Response Analysis. [PDF]
Zacarias TG +9 more
europepmc +1 more source
Metal oxide varistor (MOV) is a nonlinear resistive element whose resistance decreases rapidly when the applied voltage exceeds a threshold value. A dc solid-state circuit breaker (SSCB) uses MOVs or MOV with resistor-capacitor-diode (RCD) snubber ...
Seong Jin Lim +3 more
doaj +1 more source
STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES [PDF]
Abstrak Electric energy has been transmiting from power station to end user with transmission and distribution lines. Lightning strokes are problems that occure in transmission and distribution lines and make them fault when the electric energy were ...
Liliyana NS, Liliyana NS +2 more
core