Results 11 to 20 of about 86 (79)
The submodule in multilevel modular converters experiences a very fast transient overvoltage (VFTO) during switch operation of gas‐insulated switchgear, which also results in overvoltage on power devices, such as thyristors and insulated gate bipolar ...
Hong Shen +7 more
doaj +2 more sources
Abstract With the development of a distributed generation, direct current (DC) load and energy‐storage equipment, voltage‐source‐converter‐based medium‐voltage DC systems (VSC‐MVDC) have attracted more attention due to its low power consumption, high reliability, independent power control and so on.
Muhammad Junaid +6 more
wiley +1 more source
Varistor coupling method and recommendation parameters for combination wave test
Low‐voltage varistors are adopted here in the OrCAD/PSpice environment to analyze the influence of varistor coupling on the output characteristic of the combination wave generator (CWG). Experiments have also been conducted here, and our simulation results are found to match the experimental ones well.
Mi Zhou +6 more
wiley +1 more source
New Fault-Location Algorithm for Series-Compensated Double-Circuit Transmission Line
This paper proposes a new fault location algorithm to accurately locate the faults of series-compensated double-circuit transmission line and improve the stability of power system operation, which is not affected by fault types. The proposed algorithm is
Daiying Cai, Jun Zhang
doaj +1 more source
Electro-conductive (EC) yarns can be woven into a hybrid fabric to enable electrical current to flow through the fabric from one component A to another component B. These hybrid fabrics form the bases of woven e-textiles.
Hertleer Carla +5 more
doaj +1 more source
This article focuses on the problem that the voltage recovery time of relay protection circuits in converter stations is too long under lightning surges.
Yuqi Zhang, Weidong Zhang, Jianfei Ji
doaj +1 more source
Reduction Reactive Power and Collapse Voltage Using Series Capacitors Compensation in Sudden Change Loads of Transmission Lines [PDF]
The continuous increase of disturbances on the interconnected electric power system resulting in its inability to reliably meet demands. This paper presents an application of a series capacitor compensation in transmission line and shunt reactors ...
Hussein Thani Rishag
doaj +1 more source
Series-compensated transmission lines (SCTLs) are increasingly preferred for transmitting bulk amounts of electricity generated from the present-day large-scale wind farm to the utility grid due to several technical and economic benefits. However, when a
M. S. Prabhu +4 more
doaj +1 more source
金属氧化物压敏电阻(metal oxide varistor,MOV)广泛应用于各种直流断路器中,用于抑制过电压、系统能量耗散与开断电压建立。受目前加工工艺限制,单MOV阀片通流能力有限,故断路器中多采用多柱并联结构。柱间电流分配不均会导致局部阀片超负荷耗能,造成开断失败甚至设备损坏。文中基于实验测量建立了一种直流开断工况下的MOV电气模型,基于该模型提出了MOV阀片均流选配方法。经实验验证,传统基于雷电冲击测试方法选配的MOV在直流开断工况的均流特性不能完全满足要求 ...
龙辰 +7 more
doaj
Metal oxide varistors (MOVs) are a type of resistor with significantly nonlinear current-voltage characteristics commonly used in power lines to protect against overvoltages.
Toni Gutknecht +4 more
doaj +1 more source