Results 31 to 40 of about 181 (134)

The behaviour and performance of metal oxide varistor under the application of multiple lightning impulses / Mohd Aizad Safwan Abdul Majid [PDF]

open access: yes, 2010
The behavior and performance of lightning protective devices such as the metal oxide varistor (MOV) under the application of multiple lightning impulses are different from that of the standard single stroke test.
Abdul Majid, Mohd Aizad Safwan
core  

Control strategy of novel hybrid commutated converter based on reverse blocking integrated gate commutated thyristor for commutation failure mitigation

open access: yesHigh Voltage, Volume 10, Issue 3, Page 546-554, June 2025.
Abstract Commutation failure (CF) is an inherent problem faced by line commutated converter high voltage direct current (LCC‐HVDC) technology. To completely solve the problem of CF, we have proposed a novel hybrid commutated converter (HCC) technology based on reverse blocking integrated gate commutated thyristor, which can utilise two methods for ...
Zongze Wang   +7 more
wiley   +1 more source

Mechanism and suppression of breaking overvoltage of DC circuit breakers

open access: yesHigh Voltage, Volume 10, Issue 1, Page 32-46, February 2025.
Abstract The occurrence of breaking overvoltage in a DC circuit breaker (DCCB) poses a potential threat to the safe operation of a DC grid. Based on the structure of the ±10 kV three‐terminal DC distribution network, this paper sets up the medium‐voltage DCCB and formulates a fault protection strategy.
Lu Qu   +7 more
wiley   +1 more source

The behaviour and performance of metal oxide varistor under the application of multiple lightning impulses [PDF]

open access: yes, 2005
The behaviour and performance of lightning protective devices such as the metal oxide varistor (MOV) under the application of multiple lightning impulse are different from that of the standard single stroke test.
Yaacob, Mohd. Muhridza
core  

Study on clamping type DC circuit breaker with short fault isolation time and low energy dissipation [PDF]

open access: yes, 2023
The development of DC grids faces challenges from DC fault protection. The conventional DC circuit breaker (DCCB) employs metal-oxide varistor (MOV) to isolate the faulted line, in which the fault isolation process is coupled with the energy dissipation ...
Zhao, Xibei   +3 more
core   +1 more source

Research on influence of double energy absorptions on dynamic volt‐ampere characteristics of metal oxide varistors

open access: yesHigh Voltage, Volume 10, Issue 1, Page 78-87, February 2025.
Abstract Metal oxide varistors (MOVs) are extensively employed in DC circuit breakers (DCCBs) to suppress overvoltage, dissipate energy and build up voltage after interruption. Despite their widespread use, the performance of MOVs under short‐time, double energy absorption conditions is not well understood, posing a challenge to their application in ...
Chen Long   +5 more
wiley   +1 more source

High‐Current Cryogenic DC Solid‐State Circuit Breaker for Electric Aircraft

open access: yesIET Electric Power Applications, Volume 19, Issue 1, January/December 2025.
Cryogenic and superconducting technologies have great potential to significantly enhance the power density and efficiency of electric propulsion aircraft. This paper presents the design of a 300 V/1700 A DC solid‐state circuit breaker (SSCB) operating at cryogenic temperatures.
Zhongying Wang   +8 more
wiley   +1 more source

Cryogenic DC Circuit Breaker Based on High‐Power Press‐Pack IGBT

open access: yesIET Electric Power Applications, Volume 19, Issue 1, January/December 2025.
This paper presents the performance of cryogenically compatible 3.3 kV/1.5 kA PP‐IGBTs as the main circuit breaker in a hybrid circuit breaker. The 3.3 kV/1.5 kA press‐pack IGBT can interrupt currents exceeding 5.1 kA when immersed in a liquid nitrogen bath. PP‐IGBTs are promising candidates for high‐power circuit breakers in cryogenically cooled power
Zhongying Wang   +9 more
wiley   +1 more source

The effects of fast rise multiple lightning impulse on the electrical breakdown characteristics of MOV [PDF]

open access: yes, 2006
The behavior and performance of lightning protective devices such as metal oxide varistor under the application of multiple lightning impulses are different from the standard single stroke test.
Sin, Chock Tean
core  

Ageing Behaviours and Mechanisms of SiC MOSFET and Si IGBT in DC Solid‐State Circuit Breaker

open access: yesIET Electric Power Applications, Volume 19, Issue 1, January/December 2025.
We propose that this distributed thermal profile in IGBT mitigates localised stress. Conversely, the high concentration of thermal stress in SiC MOSFET's gate region leads to its severe ageing. ABSTRACT The rapid development of DC power systems in applications such as electric aircraft and microgrids has highlighted the need for high‐performance DC ...
Jiajia Song, Bo Zhang, Yanfeng Song
wiley   +1 more source

Home - About - Disclaimer - Privacy