Results 31 to 40 of about 2,386,087 (130)
Modeling The Metal Oxide Varistor Surge Arrester For Overhead Protection In Transmission Line [PDF]
This project focused on the modelling and analysis of Metal Oxide Varistor Surge Arrester Model Type in Transmission Line for Overhead Protection. The primary cause of damage to electrical system equipment is transient overvoltage occurring in the ...
Nur Alisah Syuhadah, Mohd Haiza
core
saidigroup/Metal-Oxide-Dataset: Metal_Oxide_dataset
Metal oxide training ...
TdS-PdV, Atari5200
core +1 more source
Metal oxide varistor (MOV) is a nonlinear resistive element whose resistance decreases rapidly when the applied voltage exceeds a threshold value. A dc solid-state circuit breaker (SSCB) uses MOVs or MOV with resistor-capacitor-diode (RCD) snubber ...
Seong Jin Lim +3 more
doaj +1 more source
Automatic generation control (AGC) is vital for preserving frequency and power balance in modern interconnected power systems (IPSs), which are increasingly challenged by nonlinear dynamics, parameter uncertainties, and unpredictable load variations.
Getaneh Mesfin Meseret, Mohammad Ghiasi
wiley +1 more source
Review and Analysis of Voltage Clamping Circuits With Low Overvoltage Ratios for DC Circuit Breakers
Voltage clamping circuits are critical components in most direct-current circuit breakers (dcCBs) to achieve ultrafast dc fault interruptions and an extended lifetime.
Shuyan Zhao +4 more
doaj +1 more source
Abstract Commutation failure (CF) is an inherent problem faced by line commutated converter high voltage direct current (LCC‐HVDC) technology. To completely solve the problem of CF, we have proposed a novel hybrid commutated converter (HCC) technology based on reverse blocking integrated gate commutated thyristor, which can utilise two methods for ...
Zongze Wang +7 more
wiley +1 more source
The behaviour and performance of metal oxide varistor under the application of multiple lightning impulses / Mohd Aizad Safwan Abdul Majid [PDF]
The behavior and performance of lightning protective devices such as the metal oxide varistor (MOV) under the application of multiple lightning impulses are different from that of the standard single stroke test.
Abdul Majid, Mohd Aizad Safwan
core
Mechanism and suppression of breaking overvoltage of DC circuit breakers
Abstract The occurrence of breaking overvoltage in a DC circuit breaker (DCCB) poses a potential threat to the safe operation of a DC grid. Based on the structure of the ±10 kV three‐terminal DC distribution network, this paper sets up the medium‐voltage DCCB and formulates a fault protection strategy.
Lu Qu +7 more
wiley +1 more source
The behaviour and performance of metal oxide varistor under the application of multiple lightning impulses [PDF]
The behaviour and performance of lightning protective devices such as the metal oxide varistor (MOV) under the application of multiple lightning impulse are different from that of the standard single stroke test.
Yaacob, Mohd. Muhridza
core
Abstract Metal oxide varistors (MOVs) are extensively employed in DC circuit breakers (DCCBs) to suppress overvoltage, dissipate energy and build up voltage after interruption. Despite their widespread use, the performance of MOVs under short‐time, double energy absorption conditions is not well understood, posing a challenge to their application in ...
Chen Long +5 more
wiley +1 more source