Results 31 to 40 of about 2,095 (173)
Προστασία επαφών ηλεκτρονόμου με varistor [PDF]
Εθνικό Μετσόβιο Πολυτεχνείο--Μεταπτυχιακή Εργασία.
Mavrakis, Vasileios +1 more
core +1 more source
Influence of UHV GIL access on transient recovery voltage of circuit breaker
The access of ultra high voltage (UHV) gas-insulated transmission line (GIL) affects both the transient recovery voltage (TRV) amplitude and the rate of rise of TRV (RRRV) of circuit breakers,which may endanger the breaking capacity of circuit breakers ...
SUN Yi +5 more
doaj +1 more source
New Fault-Location Algorithm for Series-Compensated Double-Circuit Transmission Line
This paper proposes a new fault location algorithm to accurately locate the faults of series-compensated double-circuit transmission line and improve the stability of power system operation, which is not affected by fault types. The proposed algorithm is
Daiying Cai, Jun Zhang
doaj +1 more source
Semiconductor devices in solid-state/hybrid circuit breakers: current status and future trends [PDF]
Circuit breakers (CBs) are the main protection devices for both alternating current (AC) and direct current (DC) power systems, ranging from tens of watts up to megawatts.
Alan J. Watson +8 more
core +1 more source
Automatic generation control (AGC) is vital for preserving frequency and power balance in modern interconnected power systems (IPSs), which are increasingly challenged by nonlinear dynamics, parameter uncertainties, and unpredictable load variations.
Getaneh Mesfin Meseret, Mohammad Ghiasi
wiley +1 more source
Measuring the energy handling capability of metal oxide varistors [PDF]
Metal oxide varistors are widely used in many power electronics circuits to protect against transient over voltages. Certain applications are very demanding on the energy handling capability of the varistors.
Ahmed, M. M. R. +3 more
core +1 more source
Effect of electro-thermally induced degradation on the capacitance of metal oxide varistors [PDF]
: In this study, changes in the capacitance of MOV-based arresters resulting from thermal stresses are analysed. Low-voltage MOV samples are artificially degraded at different thermal stresses, while the simultaneously applied ac field was kept constant.
Bokoro, P., Muremi, L.
core +2 more sources
Abstract Commutation failure (CF) is an inherent problem faced by line commutated converter high voltage direct current (LCC‐HVDC) technology. To completely solve the problem of CF, we have proposed a novel hybrid commutated converter (HCC) technology based on reverse blocking integrated gate commutated thyristor, which can utilise two methods for ...
Zongze Wang +7 more
wiley +1 more source
Mechanism and suppression of breaking overvoltage of DC circuit breakers
Abstract The occurrence of breaking overvoltage in a DC circuit breaker (DCCB) poses a potential threat to the safe operation of a DC grid. Based on the structure of the ±10 kV three‐terminal DC distribution network, this paper sets up the medium‐voltage DCCB and formulates a fault protection strategy.
Lu Qu +7 more
wiley +1 more source
Condition monitoring and deterioration analysis of metal oxide varistor
With the growing demand for application of metal-oxide varistor (MOV) in low-voltage electronic circuits for overvoltage protection, it is necessary to ensure its performance to avoid the short-circuit and the line-to-ground fault during operation.
Guoming Wang +3 more
semanticscholar +1 more source

