Results 41 to 50 of about 1,942,479 (324)
Uniform fractional factorial designs
The minimum aberration criterion has been frequently used in the selection of fractional factorial designs with nominal factors. For designs with quantitative factors, however, level permutation of factors could alter their geometrical structures and ...
Lin, Dennis K. J. +2 more
core +1 more source
Precise Orbit Determination Based on the Unscented Transform for Optical Observations
In this study, the precise orbit determination (POD) software is developed for optical observation. To improve the performance of the estimation algorithm, a nonlinear batch filter, based on the unscented transform (UT) that overcomes the disadvantages ...
Hyewon Hwang, Eunji Lee, Sang-Young Park
doaj +1 more source
Holographic aberration correction: optimising the stiffness of an optical trap deep in the sample [PDF]
We investigate the effects of 1st order spherical aberration and defocus upon the stiffness of an optical trap tens of μm into the sample. We control both these aberrations with a spatial light modulator. The key to maintain optimum trap stiffness over a
Bowman +22 more
core +1 more source
Some results on $2^{n-m}$ designs of resolution IV with (weak) minimum aberration
It is known that all resolution IV regular $2^{n-m}$ designs of run size $N=2^{n-m}$ where $5N ...
Chen, Hegang H., Cheng, Ching-Shui
core +1 more source
The Infrared Imaging Spectrograph (IRIS) for TMT: optical design of IRIS imager with "Co-axis double TMA" [PDF]
IRIS (InfraRed Imaging Spectrograph) is one of the first-generation instruments for the Thirty Meter Telescope (TMT). IRIS is composed of a combination of near-infrared (0.84--2.4 $\mu$m) diffraction limited imager and integral field spectrograph.
Harakawa, Hiroki +12 more
core +3 more sources
Lymphocyte chromosomal aberration assay in radiation biodosimetry
Exposure to ionizing radiations, whether medical, occupational or accidental, leads to deleterious biological consequences like mortality or carcinogenesis. It is considered that no dose of ionizing radiation exposure is safe.
Paban K Agrawala +2 more
doaj +1 more source
Analysis and interpretation of the Seidel aberration coefficients in digital holography [PDF]
Peer reviewedPublisher ...
Champagne +10 more
core +1 more source
Minimum aberration designs of resolution III
In this article we prove several important properties of 2^{k-p} minimum aberration (MA) designs with k>2, where n=2^{k-p} is the number of runs. We develop a simple method to build MA designs of resolution III. Furthermore, we introduce a simple relationship, based on product of polynomials, for computing their word-length patterns.
Juan, Jesus, Palomo, J. Gabriel
openaire +2 more sources
Quarter-fraction factorial designs constructed via quaternary codes
The research of developing a general methodology for the construction of good nonregular designs has been very active in the last decade. Recent research by Xu and Wong [Statist.
Phoa, Frederick K. H., Xu, Hongquan
core +2 more sources
ABSTRACT Background Neuropsychological complications may impair the qualitative prognosis of patients with pediatric brain tumors. However, multifaceted evaluations cannot be conducted in all patients because they are time consuming and burdensome for patients.
Ami Tabata +9 more
wiley +1 more source

