Results 41 to 50 of about 801,823 (212)

Initial Feasibility and Clinical Implementation of Daily MR-Guided Adaptive Head and Neck Cancer Radiation Therapy on a 1.5T MR-Linac System: Prospective R-IDEAL 2a/2b Systematic Clinical Evaluation of Technical Innovation [PDF]

open access: yes, 2021
Purpose: This prospective study is, to our knowledge, the first report of daily adaptive radiation therapy (ART) for head and neck cancer (HNC) using a 1.5T magnetic resonance imaging-linear accelerator (MR-linac) with particular focus on safety and ...
MR-Linac Consortium Head and Neck Tumor Site Group and the Joint Head and Neck Radiotherapy-MRI Development Cooperative
core  

Ion chamber magnetic field correction factors measured via microDiamond cross-calibration from a conventional linac to MRI-linac

open access: yes, 2022
Magnetic field correction factors are required for performing reference dosimetry on Magnetic Resonance Imaging Linear accelerators (MRI-linacs). Methods for measuring magnetic field correction factors usually require specialized equipment and expertise.
Paul Keall (10741502)   +4 more
core   +1 more source

MR-Linac: Technological innovations and comparison with high-conformation techniques in the delivery of radiotherapy treatment in patients affected by prostatic neoplasia.

open access: yes, 2022
openQuesto elaborato di tesi propone il confronto tra le tecniche ad alta conformazione utilizzate differentemente dal LINAC e dal MR-LINAC nell'erogazione della terapia, la descrizione di analogie e differenze riguardo il trattamento del carcinoma ...
FASSINA, LORENZO
core  

Evaluation of single-isocenter multiple-target IMRT using 1.5T Elekta Unity MR-guided linear accelerator for stereotactic radiosurgery of multiple brain metastases

open access: yesJournal of Radiation Research and Applied Sciences
Purpose: To assess the dosimetric performance of using the 1.5T Elekta Unity magnetic resonance (MR)-guided linear accelerator (MR-Linac) for intracranial single-isocenter, multiple-target stereotactic radiosurgery (SRS).
Shiru Zou   +8 more
doaj   +1 more source

Patterns of Care, Tolerability, and Safety of the First Cohort of Patients Treated on a Novel High-Field MR-Linac Within the MOMENTUM Study: Initial Results From a Prospective Multi-Institutional Registry

open access: yes, 2021
Purpose: High-field magnetic resonance-linear accelerators (MR-Linacs), linear accelerators combined with a diagnostic magnetic resonance imaging (MRI) scanner and online adaptive workflow, potentially give rise to novel online anatomic and response ...
MR-linac Consortium
core  

mapping on an MR‐Linac

open access: yes, 2023
BACKGROUND: T2 * mapping can characterize tumor hypoxia, which may be associated with resistance to therapy. Acquiring T2 * maps during MR-guided radiotherapy could inform treatment adaptation by, for example, escalating the dose to resistant sub-volumes.
Bano, W   +17 more
core   +1 more source

Detectability and intra-fraction motion of individual elective lymph nodes in head and neck cancer patients on the Magnetic Resonance Image guided linear accelerator

open access: yesPhysics and Imaging in Radiation Oncology
Background and purpose: Individual elective lymph node irradiation instead of elective neck irradiation is a new concept for head-and-neck cancer (HNC) patients developed for the Magnetic Resonance Image guided linear accelerator (MR-linac).
Floris C.J. Reinders   +5 more
doaj   +1 more source

Evaluation of an anthropomorphic ion chamber and 3D gel dosimetry head phantom at a 0.35 T MR-linac using separate 1.5 T MR-scanners for gel readout

open access: yesZeitschrift für Medizinische Physik, 2022
Purpose: To date, no universally accepted technique for the evaluation of the overall dosimetric performance of hybrid integrated magnetic resonance imaging (MR) – linear accelerators (linacs) is available. We report on the suitability and reliability of
Lukas Nierer   +9 more
doaj   +1 more source

Validation of echo planar imaging based diffusion-weighted magnetic resonance imaging on a 0.35 T MR-Linac

open access: yesPhysics and Imaging in Radiation Oncology
Background and Purpose: The feasibility of acquiring diffusion-weighted imaging (DWI) images on an MR-Linac for quantitative response assessment during radiotherapy was explored. DWI data obtained with a Spin Echo Echo Planar Imaging sequence adapted for
Philipp Wallimann   +10 more
doaj   +1 more source

MR‐Linac guided adaptive stereotactic ablative body radiotherapy for recurrent cardiac sarcoma with mitral valve bioprosthesis – a case report

open access: yesJournal of Medical Radiation Sciences, 2023
We present the first case in the literature of a 78‐year‐old woman with recurrent cardiac sarcoma adjacent to a bioprosthetic mitral valve treated with magnetic resonance linear accelerator (MR‐Linac) guided adaptive stereotactic ablative body ...
Vikneswary Batumalai   +8 more
doaj   +1 more source

Home - About - Disclaimer - Privacy