Abstract Background Single‐isocenter stereotactic radiosurgery enables efficient treatment of multiple brain metastases (SI‐MBM SRS), but demands high geometric accuracy. Plan complexity metrics are increasingly used as indicators for quality assurance (QA) performance, however their applicability to SRS remains uncertain, particularly in the context ...
Despoina Stasinou +6 more
wiley +1 more source
Characterization of a prototype MR-compatible Delta4 QA-system in a 1.5 tesla MR-linac [PDF]
To perform patient plan quality assurance (QA) on a newly installed MR-linac (MRL) it is necessary to have an MR-compatible QA device. An MR compatible device (MR-Delta4) has been developed together with Scandidos AB (Uppsala, Sweden).
Houweling, Anette +7 more
core +1 more source
Case Report: MR-Guided Adaptive Radiotherapy, Some Room to Maneuver
BackgroundA magnetic resonance linear accelerator (MR-Linac) provides superior soft tissue contrast to evaluate inter- and intra-fraction motion and facilitate online adaptive radiation therapy (ART).
Winnie Li +9 more
doaj +1 more source
Seeing radiation: Applications of an imaging survey meter in radiation oncology
Abstract Background and purpose Radiation shielding surveys require location and evaluation of radiation hotspots in shielding barriers. This process is normally done by using a conventional survey meter and slowly moving the survey meter manually across the face of the barrier.
Patrick N. McDermott +8 more
wiley +1 more source
Ionization chamber correction factors for MR-linacs
Previously, readings of air-filled ionization chambers have been described as being influenced by magnetic fields. To use these chambers for dosimetry in magnetic resonance guided radiotherapy (MRgRT), this effect must be taken into account by introducing a correction factor k B.
Stefan, Pojtinger +3 more
openaire +2 more sources
MRI commissioning of 1.5T MR-linac systems – a multi-institutional study [PDF]
Background: Magnetic Resonance linear accelerator (MR-linac) systems represent a new type of technology that allows for online MR-guidance for high precision radiotherapy (RT).
Paulson, Eric S. +17 more
core +2 more sources
Background The aim of this study was to evaluate and compare the performance of intensity modulated radiation therapy (IMRT) plans, planned for low-field strength magnetic resonance (MR) guided linear accelerator (linac) delivery (labelled IMRT MRL plans)
Vanessa Da Silva Mendes +9 more
doaj +1 more source
Investigations on particle dynamics in a high intensity heavy ion linac for inertial fusion [PDF]
Die Physik intensiver Ionenstrahlen wird zur Zeit für verschiedene neue Hochstrom- und Hochenergie-Beschleunigeranlagen untersucht. Ein kritischer Punkt ist dabei die Minimierung der Strahlverluste, um die Aktivierung der Beschleunigerstruktur zu ...
Parisi, Giovanni
core
Abstract Purpose To develop and evaluate a water‐profile‐based (WP) calibration method for two‐dimensional (2D) ionization chamber arrays used in medical linear accelerator (linac) quality assurance (QA), and to compare its accuracy, efficiency, and cross‐energy applicability with the manufacturer‐provided wide‐field (WF) calibration method.
Kihong Pak +12 more
wiley +1 more source
PURPOSE: This study aims to investigate a star shot analysis using a three‐dimensional (3D) gel dosimeter for the imaging and radiation isocenter verification of a magnetic resonance linear accelerator (MR‐Linac).
Park, Jong Min +20 more
core +1 more source