Results 51 to 60 of about 801,823 (212)
This review article reports that quantification of hypoxic volumes using PET in the pre‐radiation therapy setting is of prognostic value and indicative of treatment response in non‐small cell lung cancer. Abstract Introduction Non‐small cell lung cancer (NSCLC) is the leading cause of cancer‐related death. Definitive treatment includes chemotherapy and
Carol Marks, Michelle Leech
wiley +1 more source
Three dimensional simulation and magnetic decoupling of the linac in a linac-MR system [PDF]
Real time image guided radiotherapy has been proposed by integrating an in-line 6 MV linear accelerator (linac) to a magnetic resonance (MR) imager in either a parallel or transverse configuration.
St. Aubin, Joel
core +1 more source
Background and purpose: In this report, we describe our implementation and initial clinical experience using 4D-MRI driven MR-guided online adaptive radiotherapy (MRgOART) for abdominal stereotactic body radiotherapy (SBRT) on the Elekta Unity MR-Linac ...
Eric S. Paulson +9 more
doaj +1 more source
In this study, we assess the dosimetric qualities and usability of planning for 1.5 T MR-Linac based intensity modulated radiotherapy (MRL-IMRT) for various clinical sites in comparison with IMRT plans using a conventional linac.
Shouliang Ding MS +7 more
doaj +1 more source
This analysis included quantification of intrafraction motion in pancreas stereotactic ablative radiotherapy treated on the MR‐Linac, leading to the development of adjusted (PTV) margins. Intrafraction motion indicated an average target displacement of 1–3 mm, resulting in an adjusted PTV margin of 2 mm in the right–left and superior–inferior ...
Ashleigh Fasala +6 more
wiley +1 more source
Performance of a multileaf collimator system for a 1.5T MR‐linac [PDF]
PurposeThe purpose of this study was to evaluate the performance of a multileaf collimator (MLC) system for the high magnetic field of the Elekta Unity magnetic resonance linear accelerator (MR‐linac).MethodsPerformance was evaluated as recommended in AAPM Report Nos. 72 and 142, and MLC motor radiofrequency (RF) shielding was also evaluated. Fields of
Ke, Zhang +4 more
openaire +2 more sources
AimThis study aims to compare acute toxicity of prostate cancer (PCa) stereotactic body radiotherapy (SBRT) delivered by MR-guided radiotherapy (MRgRT) with 1.5-T MR-linac or by volumetric modulated arc (VMAT) with conventional linac.MethodsPatients with
Rosario Mazzola +21 more
core +1 more source
Introduction: The long-term complication rate in head-and-neck squamous cell carcinoma (HNSCC) patients caused by radiotherapy (RT) can be decreased by restricting elective neck irradiation (ENI) from large adjacent lymph node levels to only individual ...
Floris C.J. Reinders +4 more
doaj +1 more source
Background and purpose: Magnetic resonance imaging – linear accelerator (MRI-linac) systems permit imaging of tumours to guide treatment. Dynamic contrast enhanced (DCE)-MRI allows investigation of tumour perfusion.
Michael J. Dubec +13 more
doaj +1 more source
MR‐Linac Successfully Guided the Treatment of a Free‐Moving Mesenteric Mass
This case demonstrated that a mesenteric tumor could move significantly day‐to‐day in all directions with large volume change. MR‐Linac with online adaptive capability provided a superior platform to treat mobile target with significantly reduced normal tissue exposure to radiation .
Xin Wang +4 more
wiley +1 more source