Results 61 to 70 of about 1,767,691 (332)
Abstract Positron emission tomography with x‐ray computed tomography (PET/CT) is increasingly being utilized for radiation treatment planning (RTP). Accurate delivery of RT therefore depends on quality PET/CT data. This study covers quality control (QC) procedures required for PET/CT for diagnostic imaging and incremental QC required for RTP.
Ran Klein+7 more
wiley +1 more source
Some means inequalities for positive operators in Hilbert spaces
In this paper, we obtain two refinements of the ordering relations among Heinz means with different parameters via the Taylor series of some hyperbolic functions and by the way, we derive new generalizations of Heinz operator inequalities.
Jin Liang, Guanghua Shi
doaj +1 more source
Ergodic behaviors of composition operators acting on space of bounded holomorphic functions [PDF]
We completely characterize the mean ergodic composition operators on $H^\infty(\mathbb{B}_n)$. In particular, we show that a composition operator acting on this space is mean ergodic if and only if it is uniformly mean ergodic.
arxiv
Norm inequalities related to the Heron and Heinz means
In this article, we present several inequalities treating operator means and the Cauchy-Schwarz inequality. In particular, we present some new comparisons between operator Heron and Heinz means, several generalizations of the difference version of the ...
Conde, C.+4 more
core +1 more source
The number of circulating tumor cells obtained from prostate cancer patients was increased approximately 5‐fold compared to regular CellSearch when processing 2 mL diagnostic leukapheresis material aliquots and increased by 44‐fold when processing 20 mL DLA aliquots using the flow enrichment target capture Halbach‐array.
Michiel Stevens+8 more
wiley +1 more source
A small footprint couch‐top support device for image‐guided radiotherapy of heavy patients
Abstract Purpose Patients with body weights close to or above 400 lbs present unique challenges in radiation therapy since the weight limit of most treatment couches decreases as the couch‐top extends toward the treatment gantry. The purpose of this work was to develop a small footprint couch‐top support platform to safely perform image‐guided ...
Huixiao Chen+5 more
wiley +1 more source
A comparative study of circulating tumor cell isolation and enumeration technologies in lung cancer
Lung cancer cells were spiked into donor blood to evaluate the recovery rates of the following circulating tumor cell (CTC) enrichment technologies: CellMag™, EasySep™, RosetteSep™, Parsortix® PR1, and Parsortix® Prototype systems. Each method's advantages and disadvantages are described.
Volga M Saini+11 more
wiley +1 more source
Abstract Background and purpose For postoperative breast cancer patients, deformable image registration (DIR) is challenged due to the large deformations and non‐correspondence caused by tumor resection and clip insertion. To deal with it, three metrics (fiducial‐, region‐, and intensity‐based) were jointly used in DIR algorithm for improved accuracy ...
Xin Xie+6 more
wiley +1 more source
Subordination results for a class of analytic functions
In this paper, we derive several subordination results and integral means result for certain class of analytic functions with complex order defined by means of q-differential operator. Some interesting corollaries and consequences of our results are also
Aouf M. K.+2 more
doaj +1 more source
This study demonstrates that KRAS and GNAS mutations are more prevalent in patients with resected intraductal papillary mucinous neoplasms (IPMN) compared to those under clinical surveillance. GNAS mutations significantly differ between the two patient cohorts, indicating that their absence may serve as a potential biomarker to support conservative ...
Christine Nitschke+12 more
wiley +1 more source