Technical Note: Out-of-field dose measurement at near surface with plastic scintillator detector. [PDF]
Out-of-field dose depends on multiple factors, making peripheral dosimetry complex. Only a few dosimeters have the required features for measuring peripheral dose.
Bourgouin A, Varfalvy N, Archambault L.
europepmc +6 more sources
Dose Calculation Accuracy of Radiotherapy Treatment Planning Systems in Out-of-Field Regions [PDF]
no ...
Farhood B., Ghorbani M.
doaj +5 more sources
Analytical model for out-of-field dose in photon craniospinal irradiation. [PDF]
The prediction of late effects after radiotherapy in organs outside a treatment field requires accurate estimations of out-of-field dose. However, out-of-field dose is not calculated accurately by commercial treatment planning systems (TPSs). The purpose of this study was to develop and test an analytical model for out-of-field dose during craniospinal
Taddei PJ +6 more
europepmc +5 more sources
Accuracy of out-of-field dose calculations by a commercial treatment planning system. [PDF]
The dosimetric accuracy of treatment planning systems (TPSs) decreases for locations outside the treatment field borders. However, the true accuracy of specific TPSs for locations beyond the treatment field borders is not well documented. Our objective was to quantify the accuracy of out-of-field dose predicted by the commercially available Eclipse ...
Howell RM +3 more
europepmc +5 more sources
Experimental assessment of out-of-field dose components in high energy electron beams used in external beam radiotherapy. [PDF]
The purpose of this work was to experimentally investigate the out‐of‐field dose in a water phantom, with several high energy electron beams used in external beam radiotherapy (RT).
Alabdoaburas MM +7 more
europepmc +3 more sources
Accuracy and sources of error of out-of field dose calculations by a commercial treatment planning system for intensity-modulated radiation therapy treatments. [PDF]
Although treatment planning systems are generally thought to have poor accuracy for out‐of‐field dose calculations, little work has been done to quantify this dose calculation inaccuracy for modern treatment techniques, such as intensity‐ modulated ...
Huang JY, Followill DS, Wang XA, Kry SF.
europepmc +2 more sources
Nontarget and Out-of-Field Doses from Electron Beam Radiotherapy
In clinical radiotherapy, the most important aspects are the dose distribution in the target volume and healthy organs, including out-of-field doses in the body.
Natalia Matuszak +8 more
doaj +3 more sources
Measuring Out-of-Field Dose to The Whole Brain in Radiotherapy
. ABSTRACT The aim of this study is to measure out-of-field lens and thyroid doses in whole brain radiotherapy with thermoluminescence dosimeters (TLD) and compare them with treatment planning system (TPS) calculation values.
H. Demir, O. Gül, T. Tuğrul
semanticscholar +2 more sources
Estimation of Out-of-Field Dose Variation using Markus Ionization Chamber Detector [PDF]
O bjective : The aim of This work to provide evaluation for the out-of-field dose with different plan parameters as field size and depth using Markus ionization chamber detector in the measurement that are frequently used in electron and superficial ...
Ahmed M. Abdelaal +2 more
semanticscholar +3 more sources
Out-of-field dose assessment for pencil beam scanning proton radiotherapy versus photon radiotherapy for breast cancer in pregnant women [PDF]
Background and purpose: Cancer affects 1 in 1000–2000 pregnancies annually worldwide, creating challenges in balancing cancer treatment and fetal safety.
Menke Weessies +4 more
doaj +2 more sources