Results 91 to 100 of about 329,153 (310)

A Novel Solution for Overcoming Conflicts Between Line Protection and LVRT in MV Solar PV Interconnections

open access: yesIEEE Access
The implementation of low-voltage-ride-through (LVRT) requirements for distributed generation (DG) sources in medium voltage (MV) distribution networks introduce challenges for the existing protection systems.
Anoop V. Eluvathingal, K. Shanti Swarup
doaj   +1 more source

Determination of protection system requirements for DC UAV electrical power networks for enhanced capability and survivability [PDF]

open access: yes, 2011
A growing number of designs of future Unmanned Aerial Vehicle (UAV) applications utilise dc for the primary power distribution method. Such systems typically employ large numbers of power electronic converters as interfaces for novel loads and generators.
Burt, Graeme   +3 more
core   +1 more source

The ubiquitin ligase RNF115 is required for the clearance of damaged lysosomes

open access: yesFEBS Letters, EarlyView.
Upon lysosomal rupture, an E3 ubiquitin ligase RNF115 translocates from the cytosol to the damaged lysosomal membrane. Moreover, RNF115 depletion impairs the clearance of damaged lysosomes, identifying it as a key regulator of lysosomal quality control.
Sae Nakanaga   +3 more
wiley   +1 more source

Remote controlled partial discharge acquisition unit [PDF]

open access: yes, 2003
Online partial discharge (PD) analysis for underground high voltage cables has major advantages over the offline techniques. Online techniques usually involve PD data acquisition, storage and post-processing of the data.
Foo, M.H.   +3 more
core  

Organizing the interface—Plasma membrane architecture and receptor dynamics in virus‐cell interactions

open access: yesFEBS Letters, EarlyView.
Plasma membranes contain dynamic nanoscale domains that organize lipids and receptors. Because viruses operate at similar scales, this architecture shapes early infection steps, including attachment, receptor engagement, and entry. Using influenza A virus and HIV‐1 as examples, we highlight how receptor nanoclusters, multivalent glycan interactions ...
Jan Schlegel, Christian Sieben
wiley   +1 more source

1.7 kV IGBT Driver Based on Electromagnetism Isolation

open access: yesKongzhi Yu Xinxi Jishu, 2015
The basic characteristics of IGBT driver were analyzed and an IGBT driver based on electromagnetism isolation was designed. Chopping and short-circuit test researches on the driver were executed.
XIE Shunmeng   +4 more
doaj  

Reliability analysis of distribution systems with photovoltaic generation using a power flow simulator and a parallel Monte Carlo approach [PDF]

open access: yes, 2016
This paper presents a Monte Carlo approach for reliability assessment of distribution systems with distributed generation using parallel computing. The calculations are carried out with a royalty-free power flow simulator, OpenDSS (Open Distribution ...
Guerra Sánchez, Luis Gerardo   +1 more
core   +2 more sources

Degradation mechanism of the von Willebrand factor A2 domain by nattokinase

open access: yesFEBS Letters, EarlyView.
Nattokinase, a natto‐derived protease, exhibits potent antithrombotic effects. This study demonstrates that nattokinase directly cleaves the von Willebrand factor (vWF) A2 domain in vitro. Unlike the native regulator ADAMTS13, nattokinase degrades folded vWF independently of shear stress.
Ryuichi Hyakumoto   +3 more
wiley   +1 more source

PEMBUATAN PROTOTYPE PERANGKAT PHASA FAILURE PADA PANEL HUBUNG BAGI MENGGUNAKAN TEKNOLOGI PLC S7-1200 DAN SCADA INITION [PDF]

open access: yes
Industrial equipment that is always working requires continuous voltage with parameters according to the needs of each device, wherein one system can provide a voltage supply and be safe from reach, namely using a PHB known as a switch panel.
Darmawan, Amirul
core  

Power quality in high-tech campus: an exemplary case study [PDF]

open access: yes, 2013
This paper presents preliminary results from a power quality audit conducted at a high-tech campus over last year. Voltage and current were measured at various R&D buildings.
González, Juan J.   +3 more
core  