Results 101 to 110 of about 25,763 (311)
Overhead electricity line connector tester
Assessment of the condition of connectors in the overhead electricity network has traditionally relied on the heat dissipation or voltage drop from existing load current (50Hz) as a measurable parameter to differentiate between satisfactory and failing ...
McIvor, Kenneth Courtney
core
Tap-Off Power From the Overhead Shield Wires of an HV Transmission Line
In recent years, there was an increase of ancillary service loads, such as signaling systems, inspection robots, surveillance cameras, and other monitoring devices distributed along high-voltage transmission lines which require low-power dc voltage ...
Jardini, Jose Antonio +4 more
core +1 more source
Reconfigurable Selector‐Only Memory (SOM) for Scalable Neuromorphic Computing
ABSTRACT Highly scalable reconfigurable neuromorphic devices are critical for addressing continual‐learning challenges in artificial intelligence. However, the scalability of existing reconfigurable devices is severely constrained by limited operating margins and insufficient process maturity.
Jin‐Yu Wen +7 more
wiley +1 more source
Real‐Time overhead Power Line Sag Monitoring
System and method for determining real-time sag and shape information of an electrical power line based on strain distribution along a length of an optical fiber associated with the power line.
Bo, Rui, Huang, Jie
core +1 more source
Thin‐Film Transistor Based Active Taxel for Multimode Tactile Perception and Fused Processing
Skin serves as the largest‐area organ for human and embodied intelligent robots, providing tactile interaction. An active multimode fused (AMF) artificial skin is developed using standard TFT processes, featuring 2T‐1C taxels with optical and electrostatic capacitive receptors for cross‐modal sensing.
Sihao Wu +13 more
wiley +1 more source
Power Minimisation Techniques for Testing Low Power VLSI Circuits (PhD Dissertation)
Testing low power very large scale integrated (VLSI) circuits has recently become an area of concern due to yield and reliability problems. This dissertation focuses on minimising power dissipation during test application at logic level and register ...
Nicolici, N.
core
LIGHTNING SIMULATION STUDY ON LINE INSULATORS (Surge arresters) (110kV Overhead Power Line "Fierze F. Arrez - HC Dardhe") [PDF]
During the designing phase of the line of a private power plant was made a study of howthe atmospheric discharges from lighting impulses could affect the working regime of a newpower Hydro Power plant under construction in the Dardhe Puke Area.The line ...
Aldi Mucka; Departament of Electrical Systems of Power, Polytechnic University of Tirana +1 more
core
A diagnostic method for reconfigurable intelligent surfaces (RIS) based on non‐uniform space‐time‐coding modulation is presented. Fault localization is achieved via amplitude‐only spectral measurements, eliminating the need for complex signal processing. A one‐to‐one mapping between harmonic components and RIS elements enables accurate detection.
Xiao Qing Chen +8 more
wiley +1 more source
Mapeamento do risco térmico em linhas aéreas de transmissão com base em dados de modelo numérico atmosférico [PDF]
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-graduação em Engenharia Mecânica, Florianópolis, 2010Este trabalho tem o objetivo de fazer o mapeamento do risco térmico em linhas aéreas de transmissão ...
Sakagami, Yoshiaki
core
Behavior Of Overhead Transmission Line Parameters On The Presence Of Ground Wires
Initially this paper shows the ground wire reduction process for generic multiphase transmission lines and after, the ground wire reduction process for a specific 440-kV three-phase overhead transmission line.
Portela C.M. +4 more
core +1 more source