Results 31 to 40 of about 534,382 (201)
With the rapid development of DC grids, resonant DC circuit breakers (RDCBs) have become critical for fault isolation. However, existing RDCBs often suffer from severe energy mismatches, and components, including mechanical switches, resonant capacitors,
Yumin Zhang +4 more
doaj +2 more sources
As a predominant issue within line-commutated converters-based high voltage direct current (DC) transmission systems, commutation failure may trigger transient overvoltage problems and the tripping of large-scale renewable generation sets in hybrid AC/DC
Boyu Qin +4 more
doaj +2 more sources
In this study, a LCC-VSC hybrid HVDC transmission system was taken as an example. The valve and neutral overvoltage of the hybrid HVDC system were simulated and then calculated at the VSC converter station by installing a blocking diode and a DC circuit ...
Wang Dongju, Zhou Hao
doaj +1 more source
Overvoltage and Oscillation Suppression Circuit With Switching Losses Optimization and Clamping Energy Feedback for SiC MOSFET [PDF]
The snubber circuit is a cost-effective solution to reduce the severe turn-off overvoltage and oscillation caused by the fast switching characteristics of SiC MOSFET.
Yang, Chengzi +11 more
core +1 more source
Aiming at the transient overvoltage problem of high proportion new energy multi direct current (DC) transmission system caused by DC blocking fault, the interaction mechanism between multiple DC lines is analyzed firstly and the multi-outfeed voltage ...
ZHANG Qirui +5 more
doaj +1 more source
Insulator fault feature extraction system of substation equipment based on machine vision
Abstract The artificial intelligence technology and intelligent automation are more and more widely used, the insulators play a supporting and insulating role in the operation of the grid. The use of machine vision inspection technology to detect insulator faults has become an inevitable trend of the times.
Keruo Jiang +4 more
wiley +1 more source
The series line-commutated converter (LCC) and modular multilevel converter (MMC) hybrid high-voltage direct current (HVDC) system provides a more economical and flexible alternative for ultra-HVDC (UHVDC) transmission, which is the so-called Baihetan ...
Xiaodong Li, Zheng Xu, Zheren Zhang
doaj +1 more source
Voltage source converter based high voltage direct current (VSC-HVDC) has a broad application prospect in the field of islanded renewable energy transmission, due to its advantages such as no commutation failure. When AC fault occurs in the AC power grid
YU Xiao, BU Guangquan, WANG Shanshan
doaj +1 more source
During the switching operation of the non-load power transmission lines, the undisired switching overvoltage issue is inevitable, causing grid voltage oscillations, waveform distortion and other phenomena at the end of the non-load power transmission ...
Bo Yang +4 more
doaj +1 more source
Aiming at the problem of overvoltage caused by ferromagnetic resonance fault of 220 kV CVT (capacitive voltage transformer) and the problem of false alarm of 3U0 monitoring device, a simulation model is established based on actual parameters, and the ...
LI Bowen +5 more
doaj +1 more source

