Results 41 to 50 of about 420,105 (198)

Mechanism of Quasi‐Power‐Frequency Resonant Overvoltage Triggered by Multiple Lightning Strikes in High‐Voltage Alternating Current Systems Equipped With Shunt Reactor

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang   +7 more
wiley   +1 more source

Electromagnetic transient suppression for thyristor switch‐based auto‐passing neutral section system

open access: yesIET Power Electronics, 2023
The auto‐passing neutral section (ANS), applied in the traction substation or section post (SP), is one of the effective methods to improve the continuity of power supply, and the electromagnetic transient is the key issue impacting its application value.
Wu Liran   +3 more
doaj   +1 more source

Research on switching overvoltage suppression of 35 kV shunt reactor

open access: yesJournal of Physics: Conference Series, 2020
Abstract In recent years, a number of equipment abnormal events caused by operating overvoltage have occurred during the interruption of 35 kV shunt reactors, which jeopardizes the safe and stable operation of the grid. In order to explore the mechanism of operating overvoltage when 35 kV shunt reactor is cut off and the effect of ...
Bing Yu   +4 more
openaire   +1 more source

The Impact of Various Contact Structures on the Microscopic Surface Condition of Vacuum Interrupters During Capacitive Switching

open access: yesHigh Voltage, EarlyView.
ABSTRACT The double‐break vacuum circuit breakers (VCBs) that utilize series break technology effectively increase the switching capability for capacitive currents, elevate the withstand voltage level, and reduce the likelihood of restrike, all without compromising the breaking capacity for short‐circuit currents.
Yun Geng   +6 more
wiley   +1 more source

Zero‐Current Switching Based Model Predictive Control of a Double‐Extended Overlapped Alternate Arm Converter Used in the VSC–HVDC System

open access: yesHigh Voltage, EarlyView.
ABSTRACT The alternate arm converter (AAC) is one of the most efficient multilevel topologies based on voltage source converters (VSCs), which has recently gained attention in various applications, particularly in high voltage direct current (HVDC) systems.
Ehsan Akbari, Milad Samady Shadlu
wiley   +1 more source

Comprehensive Design and Experimental Validation of 30 kV Ultra‐Fast Flexible Controllable Arresters for HVDC Systems

open access: yesHigh Voltage, EarlyView.
ABSTRACT To effectively suppress transient overvoltages in HVDC systems, the design and experimental validation of a multi‐module series controllable arrester are presented. The voltage‐limiting performance, series voltage equalisation capability, and robustness under fault conditions in high‐voltage scenarios require further research.
Tai Yang   +4 more
wiley   +1 more source

Study on the Power‐Frequency Arc Extinction Characteristics of Semi‐Closed Short‐Gap Device

open access: yesHigh Voltage, EarlyView.
ABSTRACT Multi‐chamber arc‐extinguishing devices have a simple structure and excellent arc‐extinguishing performance; thus, they have attracted considerable attention as lightning protection devices. However, the structural parameters of different models of the aforementioned devices vary, leading to inconsistent protection levels; therefore, the arc ...
Yeqiang Deng   +4 more
wiley   +1 more source

Switching transients caused by vacuum circuit breakers in collection grids of offshore wind farms

open access: yesWind Energy, 2021
In this study, transients that can occur in the collection grids of offshore wind farms were investigated. On the basis of the multiple prestrike and reignition model that can reflect the actual operation of a vacuum circuit breaker (VCB), a switching ...
Jiayuan Tao   +6 more
doaj   +1 more source

Research Progress in Treeing Phenomena of Polypropylene Insulation Materials

open access: yesHigh Voltage, EarlyView.
ABSTRACT Polypropylene (PP) is increasingly utilised in high‐voltage systems due to its superior electrical and thermal properties. However, electrical treeing poses a significant threat to its long‐term reliability, potentially leading to insulation failure.
Boxue Du, Heyu Wang, Zhonglei Li
wiley   +1 more source

Research on transient AC overvoltage suppression method of DC sending end based on novel fast-excitation MCR

open access: yesInternational Journal of Electrical Power & Energy Systems
The growing reliance on high-power high-voltage direct current (HVDC) transmission systems has intensified challenges associated with transient AC overvoltage induced by commutation failures resulting from converter operation characteristics.
Xiyu Yin   +6 more
doaj   +1 more source

Home - About - Disclaimer - Privacy