Partial discharge testing of defective three-phase PILC cable under rated conditions

open access: yes, 2011
The ability to accurately monitor the health of power distribution plant is a very attractive prospect for utility companies. This capability would provide a system that engineers could use to assess the real-time state of the network.
Hunter, J.A.   +5 more
core   +1 more source

Implementation and Analysis of a Reference Partial Discharge Measurement System

open access: yes, 2018
Partial discharge (PD) detection is based on the measurement of apparent charge originated from PD in test sample. Since the measurement system configuration affects the PD measuring system response, a PD reference calibrator is the most important part ...
Karaman, İsmail   +5 more
core   +1 more source

An electrical PD location method applied to a continuous disc type transformer winding [PDF]

open access: yes, 2003
A 6.6 kV continuous disc type winding of a distribution transformer is used to investigate the propagation of partial discharges (PD) with the aim of location. The winding was modelled, as multiconductor transmission lines with each turn represented by a
Darwin, A.   +5 more
core  

Partial Discharge Monitoring of Power Transformers by Calibrated UHF Measurements

open access: yesJournal of Energy : Energija
Partial discharge (PD) measurement is an established technique to detect local defects in the oil/paper insulation. They can be measured by electrical PD measurements according to IEC 60270 or by electromagnetic measurements in the ultra-high frequency range (UHF: 300 MHz – 3 GHz).
Siegel, Martin   +4 more
openaire   +2 more sources

Radiometric Wireless Sensor Network Monitoring of Partial Discharge Sources in Electrical Substations [PDF]

open access: yes, 2015
A wireless sensor network (WSN) with the potential to monitor and locate partial discharge (PD) in high-voltage electricity substations using only received signal strength (RSS) is proposed.
Jaber, Adel   +28 more
core   +1 more source

Partial Discharge Calibrator Prototype [PDF]

open access: yes, 2013
In contemporary calibrators two pulses are most often used for the test voltage (100 – to 120 pulses per second). The value of the charge transferred by the pulse can be specified by registering the current pulse on the resistor using an oscilloscope ...
Paduch, P.
core  

Practical application of on-line partial discharge monitoring technique on 500kV shunt reactor

open access: yes, 2003
Considering the damage mechanism of oil-impregnated paper insulation in power transformers, shunt reactors and other high voltage electrical apparatus caused by partial discharge, a concept of “destructive partial discharge” is introduced in this paper ...
Fu, M, Wang, S, Chen, G
core   +1 more source

A matlab simulink model for a partial discharge measuring system

open access: yes, 2015
Failures in high voltage equipment are often caused due to internal faults which cause a local electrical stress concentration in the insulation; called as partial discharge.
Gunawardana, SDMS   +5 more
core  

Use of Machine Learning for Partial Discharge Discrimination

open access: yes, 2009
Partial discharge (PD) measurements are an important tool for assessing the condition of power equipment. Different sources of PD have different effects on the insulation performance of power apparatus.
Hao, L, Swingler, S G, Lewin, P L
core   +1 more source

Modelling of Partial Discharge Behaviour in a Spherical Cavity within a Solid Dielectric Material as a Function of Temperature

open access: yes, 2010
Partial discharge (PD) is an electrical discharge within a dielectric which does not bridge the electrodes. PD measurement has been widely used for assessing performance of insulation systems.
P L Lewin   +5 more
core   +1 more source