Results 21 to 30 of about 2,395,295 (133)

Application of Charge-Sensitive Preamplifier for the Calibration of Partial Discharge Calibrators Below 1 pC [PDF]

open access: yesIEEE Transactions on Instrumentation and Measurement, 2018
Presented at the 2018 Conference on Precision Electromagnetic Measurements (CPEM 2018).
Hällström, Jari, Havunen, Jussi
openaire   +7 more sources

A frequency-based RF partial discharge detector for low-power wireless sensing [PDF]

open access: yes, 2010
Partial discharge (PD) monitoring has been the subject of significant research in recent years, which has given rise to a range of well-established PD detection and measurement techniques, such as acoustic and RF, on which condition monitoring systems ...
Baker, P.C.   +2 more
core   +4 more sources

Precision Calibration System for Partial Discharge Calibrators

open access: yesProceedings of the Nordic Insulation Symposium, 2019
Partial discharge calibrators need to be periodically calibrated traceable to national standards. VTT MIKES, the National Metrology Institute (NMI) of Finland, has official expertise to calibrate the apparent charge of PD calibrators from 1 pC to 100 nC according to IEC 60270.
Hällström, Jari, Havunen, Jussi
openaire   +3 more sources

Firmware for partial discharge calibrator

open access: yes, 2022
The goal of this thesis is to create a firmware which realizes processor control for a given hardware (calibrator of partial discharge meters). Thesis describes what options are availible in the field of processor control of devices, their advantages ...
Turinský, Matěj
core   +1 more source

Identifying harmonic attributes from online partial discharge data [PDF]

open access: yes, 2011
Partial discharge (PD) monitoring is a key method of tracking fault progression and degradation of insulation systems. Recent research discovered that the harmonic regime experienced by the plant also affects the PD pattern, questioning the conclusions ...
Rowland, S.M.   +4 more
core   +3 more sources

Remote controlled partial discharge acquisition unit [PDF]

open access: yes, 2003
Online partial discharge (PD) analysis for underground high voltage cables has major advantages over the offline techniques. Online techniques usually involve PD data acquisition, storage and post-processing of the data.
Pearson, J.S.   +3 more
core   +2 more sources

Interpretation of wavelet analysis and its application in partial discharge detection. [PDF]

open access: yes, 2002
The objective of the paper is to discuss a tool which is proving extremely efficient in partial discharge measurement studies. Though the technique itself is not new, its application to partial discharge studies is.
Zhou, Chengke   +6 more
core   +5 more sources

Development of an integrated low-power RF partial discharge detector [PDF]

open access: yes, 2009
This paper presents the results from integrating a low-power partial discharge detector with a wireless sensor node designed for operating as part of an IEEE 802.15.4 sensor network, and applying an on-line classifier capable of classifying partial ...
Stephen, B.   +3 more
core   +4 more sources

Calibration Technology and Application of Ultrasonic Sensor for Partial Discharge Detector [PDF]

open access: yesProceedings of the 5th International Conference on Advanced Design and Manufacturing Engineering, 2015
Guangke Xu 1, a , Fuchun Sun, Weiwei Zhang , Ming Li , Zhenhua Zhu, Andong Wang , Fuqiang Zhao 1,g , Jie Liu , and Xiuzhong Gong 1 State Grid Shandong Electric Power Research Institute, Jinan, 250002, China 2 State Grid Yantai Power Supply Company, Yantai, 264000, China 3 Shandong Zhongshiyitong Group Co., Ltd. Jinan, 250002, China xuguangkesd@163.com,
Xiuzhong Gong   +8 more
openaire   +1 more source

Research on Calibration Technology of TEV Partial Discharge Smart Sensors

open access: yesJournal of Physics: Conference Series, 2021
Abstract TEV partial discharge detection is an important method to judge the insulation status of the switchgear. However, the quality of TEV smart sensors produced by different manufacturers on the market is uneven. Some TEV smart sensors that have been put into operation have deficiencies in measurement sensitivity, data stability, and
Hongming Shao, Zhiguo Tang
openaire   +1 more source

Home - About - Disclaimer - Privacy