Due to the increased utilization of electric converters feeding rotating high voltage motors, their insulation is subject to transient impulse and high frequency oscillating voltages.
Karsten Backhaus +2 more
doaj +1 more source
Partial discharges measurement is one of the most useful tools for condition monitoring of high-voltage (HV) equipment. These phenomena can be measured on-line in radiofrequency (RF) with sensors such as the Vivaldi antenna, used in this paper, which ...
Ricardo Albarracín +3 more
semanticscholar +1 more source
A BN@G‐POSS/EP nanocomposite is developed for high‐frequency transformer insulation in power electronic transformers. Through synergistic interface engineering, it simultaneously enhances thermal conductivity, reduces viscosity, and improves electro‐thermal stability.
Jun Jiang +6 more
wiley +1 more source
The correct identification of partial discharges (PDs) is instrumental for the maintenance plan in gas-insulated systems (GIS). However, onsite PD measurements are difficult, especially in HVDC systems, where partial discharges can be confused with ...
Christian Mier +3 more
doaj +1 more source
Partial discharge (PD) characteristics are inherently linked to associated electrical tree growth characteristics. This paper employs both phase-resolved patterns and pulse-sequence analysis (PSA) to study PDs in a short branch-tree grown from a metallic needle tip.
Lv, Zepeng +4 more
openaire +3 more sources
Finite-difference time-domain simulation of partial discharges in a gas insulated switchgear
It is important to estimate the current magnitude and charge amount of a partial discharge (PD) in a gas-insulated switchgear (GIS). In this study, electromagnetic fields generated by a PD in an 84 kV-class three-phase GIS for testing have been measured ...
Hiroki Tanaka +6 more
semanticscholar +1 more source
Multiferroic order parameters – polarization, magnetization, and ferroelastic strain – are positioned as dynamic design variables for batteries. Their mechanistic roles, practical tuning through fabrication and external fields, and ferroic‐resolved characterization routes are unified into a closed‐loop framework, revealing how coupled ferroic responses
Jiaqi Su +13 more
wiley +1 more source
Evaluation of Partial Discharge Separation Techniques
Partial discharge (PD) analysis is widely recognized as a valuable technique for detecting faults and evaluating the condition of electrical system assets. However, its practical application poses significant challenges.
Joao Victor Jales Da Silva Melo +7 more
doaj +1 more source
Allosteric Inhibition of Polycomb Repressive Complex 2 by an EZH2‐Selective Small Molecule Inhibitor
The study characterizes C36, a highly selective EZH2/PRC2 inhibitor that acts via a novel allosteric mechanism. Unlike previous inhibitors, C36 inhibits EZH2/PRC2 by disrupting the allosteric communication between EZH2 and EED in a SAM‐noncompetitive manner.
Ting Cao +11 more
wiley +1 more source
All‐Flex Plasma Patch for In Vivo Delivery of Reactive Species
A fully flexible plasma patch enables stable, conformal treatment on complex biological surfaces and enhances transdermal delivery of reactive species. This platform achieves significant tumor suppression in vivo and reveals coordinated regulation of calcium signaling, metabolism, and programmed cell death, providing a promising strategy for safe and ...
Luxiang Zhao +8 more
wiley +1 more source