Results 71 to 80 of about 75,526 (309)
Decomposition Characteristics of SF6 and Partial Discharge Recognition under Negative DC Conditions
Four typical types of artificial defects are designed in conducting the decomposition experiments of SF6 gas to obtain and understand the decomposition characteristics of SF6 gas-insulated medium under different types of negative DC partial discharge (DC-
Ju Tang +5 more
doaj +1 more source
ABSTRACT Molybdenum disulfide (MoS2) has attracted attention as a promising material due to the growing demand for environmentally friendly, cost‐effective, and efficient water treatment techniques. With its physicochemical characteristics, this stratified bidimensional material allows it to be highly effective in adsorption and catalytic performance ...
Pariksha Bishnoi +4 more
wiley +1 more source
Partial Discharge Source Classification in Power Transformers: A Systematic Literature Review
Power transformers, like other High-Voltage (HV) electrical equipment, experience aging and insulation degradation due to chemical, mechanical and electrical forces during their operation. Partial discharges (PD) are among the most predominant insulation
Lucas T. Thobejane, Bonginkosi A. Thango
doaj +1 more source
Partial discharge (PD) monitoring is widely used in rotating machines to evaluate the condition of stator winding insulation, but its practice on a large scale requires the development of intelligent systems that automatically process these measurement ...
R. D. Oliveira +7 more
semanticscholar +1 more source
We introduce an additively manufactured bioreactor with a perfusion flow system and integrated temperature and pH sensors for skeletal muscle tissue biofabrication. The bioreactor's performance was evaluated by assessing the viability, spreading of the myoblast cells in a printed scaffold, and contraction of the isolated murine musculi interossei ...
Lys Sprenger +9 more
wiley +1 more source
This paper compared the capabilities of the artificial neural network (ANN) and the fuzzy logic (FL) approaches for recognizing and discriminating partial discharge (PD) fault classes.
Abdullahi Abubakar Mas’ud +4 more
doaj +1 more source
Intelligent Sky Guardians (InSkyGuard) is introduced as a four‐drone swarm that autonomously detects, tracks, and safely captures rogue drones using a coordinated net system. Computer vision and leader–follower control architecture enable synchronized enclosure, while integrated failsafes enhance system reliability. Validated through closed‐environment
Joshua Hastings +6 more
wiley +1 more source
Partial Discharges Acceptance Criteria for AC Rotating Machines Insulation Systems
A new pass/fail criterion based on the shape analysis of phase-resolved Partial Discharges (PRPD) patterns is proposed in this study to overcome the problems generated by the use of partial discharge (PD) amplitude threshold levels.
Alfredo Contin, Andrea Piccolo
doaj +1 more source
Partial discharge (PD) detection is essential to the operation of high-voltage systems. In this context, we investigate the basic characteristics of light emission during PDs in SF 6 gas from the perspective of insulation diagnosis.
Ming Ren, M. Dong, Jialin Liu
semanticscholar +1 more source
The cellular actors of oxytocin signaling are under intense scrutiny. A brain‐wide anatomical and functional analysis in mice and rats reveals widespread expression of oxytocin receptors in astrocytes. These receptors are functionally active and, in the nucleus accumbens, selectively regulate male social affiliation.
Clémence Denis +32 more
wiley +1 more source

