2016 Biennial International Conference on Power and Energy Systems: Towards Sustainable Energy (PESTSE), 2016
In high voltage (HV) electrical power systems; varieties of materials (solid, liquid and gaseous) are used for insulation purpose to protect the early failure in High Voltage power equipment. Most of insulating materials are not perfect in all respect and contain some impurities.
Devendra Gowda, null Anandraj
openaire +1 more source
In high voltage (HV) electrical power systems; varieties of materials (solid, liquid and gaseous) are used for insulation purpose to protect the early failure in High Voltage power equipment. Most of insulating materials are not perfect in all respect and contain some impurities.
Devendra Gowda, null Anandraj
openaire +1 more source
Partial discharge. VI: PD testing of printed circuit boards
IEEE Electrical Insulation Magazine, 1991For pt.V see ibid., vol.7, no.2, p.28 et seq. (1991). The results of a research program concerned with applying partial-discharge (PD) testing to the nondestructive evaluation of the dielectric characteristics of coated printed circuit board (PCB) systems that must meet the high-voltage dielectric test requirements of low-voltage equipment are reported.
H. Koch +3 more
openaire +1 more source
Partial discharge. VIII. PD testing of solid dielectric cable
IEEE Electrical Insulation Magazine, 1991For pt.VII see ibid., vol.7, no.4, p.9 (1991). The development of solid dielectric cable is discussed and its potential defects are described. Limitations to partial discharge (PD) measurement and testing are discussed, and its use for detecting cavities (also referred to as voids), which are probably the most common defect in solid dielectric cable ...
J.C. Chan +3 more
openaire +1 more source
Experiences in on-site partial discharge measurements and prospects for PD monitoring
2008 International Conference on Condition Monitoring and Diagnosis, 2008With four case studies (dry-type transformer, power transformer, GIS, generator) this paper describes the principle of synchronous multi-channel PD measurements and its benefits for PD data evaluation. With respect to monitoring the tracing of a charge value as QIEC over the measuring time is not sufficient to assess the PD activity of an HV apparatus.
K. Rethmeier +6 more
openaire +1 more source
Analysis of Internal Partial Discharge Based on PD Current Waveform
2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena, 2008The analysis of partial discharge (PD) phenomenon to cause long-term degradation of electrical insulation systems is essential to development of electrical insulation technology. The PD pattern on the relation between PD magnitude and the phase of applied voltage is well known one of the electrical insulation diagnosis methods for high voltage ...
Kenji Nanao +2 more
openaire +1 more source
Noise Rejection and Detection of Partial Discharges Under Repetitive Impulse Supply Voltage
IEEE transactions on industrial electronics (1982. Print), 2020Partial discharge (PD) detection is a fundamental tool for the design and diagnosis of insulation systems, particularly organic materials that must operate throughout their life without PD.
Riddhi Ghosh +3 more
semanticscholar +1 more source
Partial discharges in HV machines; initial considerations for a PD specification
IEE Proceedings A Science, Measurement and Technology, 1993Partial discharge (PD) specifications exist for all types of electrical equipment except motors and generators. Whereas specifications essentially require that the equipment is discharge-free the stator conductor bar insulation of the motors and generators under consideration is micaceous and has excellent PD resistance.
J.W. Wood +4 more
openaire +1 more source
Effect of magnetic nanoparticles on partial discharges in transformer oil
, 2020We report on an experimental study of partial discharges (PD) in transformer oil with four different volume concentrations of superparamagnetic iron oxide nanoparticles (SPION) ranging from 0 to 0.0004 vol%. To investigate the PD, a specific high-voltage
J. Kurimský +5 more
semanticscholar +1 more source
Partial discharge (PD) measuring techniques
15th IET International School on High Voltage Engineering and Testing 2008, 2008The physical background of partial discharges will be explained on simple models. The requirements on the complete partial discharge measuring systems including the calibration and evaluation of the measuring results will be discussed and examples of partial discharge measurements on transformers in the laboratory and on site will be presented. Finally
openaire +1 more source
PDTools: A toolbox of partial discharge (PD) signal analysis for transformer condition assessment
2017 IEEE Power & Energy Society General Meeting, 2017Partial discharge (PD) measurement of power transformers provides a means for condition assessment of their insulation systems. To reach an informed assessment on the condition of a transformer's insulation system, it needs to appropriately analyze the measured PD signals. Though abundant methods have been proposed for PD signal analysis, it is still a
Ma, Hui +4 more
openaire +2 more sources