Results 281 to 290 of about 3,088,305 (335)
Some of the next articles are maybe not open access.

Partial Discharges in Motor Fed by Inverter: From Detection to Winding Configuration

IEEE transactions on industry applications, 2019
This paper reports non-intrusive partial discharge (PD) investigations on aeronautic and electric vehicle motors fed by inverter drive under variable environmental conditions.
C. Abadie, T. Billard, T. Lebey
semanticscholar   +1 more source

Partial discharge. XI. Limitations to PD as a diagnostic for deterioration and remaining life

IEEE Electrical Insulation Magazine, 1992
For pt.X see ibid., vol.8, no.1, p.16 (1992). The correlation of partial discharge (PD) measurements with insulation degradation and failure is addressed. The limitations inherent to such diagnostics as applied to solid insulating systems are examined.
C. Laurent, C. Mayoux
openaire   +1 more source

Partial discharge. V. PD in polymer-type line insulators

IEEE Electrical Insulation Magazine, 1991
For pt.IV see ibid., vol.7, no.1, p.20 (1991). Some of the problems related to corona and partial discharge damage to polymer insulators are outlined. The basic construction of polymer insulators for overhead lines, which consist of a core, weathersheds, and metal end fittings, is described.
openaire   +1 more source

Development of a partial discharge emulator for calibration of a radiometric PD detection system

2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings, 2012
A purely electronic partial discharge emulator for use in a location estimation algorithm for online partial discharge detection is proposed as a low-cost approach to real-time condition monitoring, asset management and operation optimization in future smart grid. Some early progress in the development of subsystems (specifically the radiometer antenna
J. M. R. de Souza Neto   +5 more
openaire   +1 more source

Localization of Partial Discharges Inside a Transformer Winding Using a Ladder Network Constructed From Terminal Measurements

IEEE Transactions on Power Delivery, 2018
Precise localization of partial discharge (PD) inside a power transformer winding is a challenging task. Previously, researchers have used internal calibration or reference signals to locate the PD source.
Mithun Mondal   +2 more
semanticscholar   +1 more source

Interference analysis and rejection of partial discharge (PD) monitoring signal on-site

Proceedings of 2001 International Symposium on Electrical Insulating Materials (ISEIM 2001). 2001 Asian Conference on Electrical Insulating Diagnosis (ACEID 2001). 33rd Symposium on Electrical and Electronic Insulating Materials and Applications in System, 2002
According to the waveform and spectrum characteristics, various interferences during on-line PD measurement could be divided into three types such as the sinusoidal continuous noises, pulse shaped interference (including the periodical and stochastical) and background noises (similar to the white noise).
null Xiaoning Wang   +2 more
openaire   +1 more source

Initiation and formation of partial discharges (PD) in mineral based insulating oil

Proceedings of 1993 IEEE 11th International Conference on Conduction and Breakdown in Dielectric Liquids (ICDL '93), 1994
This paper reports the results of fundamental investigations concerning the behavior of partial discharges (PD) in mineral-based oil with the aim of characterizing the physical mechanisms that lead to the initiation and formation of PD pulses. First the influence of the parameters temperature, moisture, pressure and oil condition on the PD inception ...
H. Borsi, U. Schroder
openaire   +1 more source

Model for partial discharges associated with treeing breakdown: I. PDs in tree channels

Journal of Physics D: Applied Physics, 2000
In order to check our physical model for partial discharges (PDs) in a tree channel, the light emission from a PD in an actual tree was observed. The experimental results agreed with the model. By using the model, conditions for the formation of typical phase-amplitude-number (-q-n) pattern of PDs from treeing was discussed.
Kai Wu   +3 more
openaire   +1 more source

Partial discharge. XVI. Ultrasonic sensing of PD within large capacitors

IEEE Electrical Insulation Magazine, 1993
For pt.XV see ibid., vol.8, no.6, p.37 et seq. (1993). High-voltage capacitor technology is reviewed, and the characteristics of partial discharges (PDs) in these capacitors, the PD's ultrasonic signatures, and the effects of acoustic attenuation within capacitor windings are discussed.
openaire   +1 more source

PD data analysis and evaluation of partial discharge patterns for uniform characterisation

IEE Proceedings - Science, Measurement and Technology, 2004
A modern partial discharge (PD) analyser provides a complete record of PD events obtained during the time of observation. A variety of analysis techniques can be applied to the data to extract characteristic information. An analysis technique that would support instrument-independent characterisation needs to have a method of identifying characteristic
openaire   +1 more source