Results 291 to 300 of about 3,088,305 (335)
Some of the next articles are maybe not open access.
Partial discharge. VII. Practical techniques for measuring PD in operating equipment
IEEE Electrical Insulation Magazine, 1991For pt.VI see ibid., vol.7, no.3, p.9 (1991) Online partial-discharge (PD) tests for monitoring the condition of the solid dielectric insulation in high-voltage equipment are discussed. Sources of external electrical noise are identified, as are attributes of PD and noise that are helpful in drawing distinctions between them. Methods for distinguishing
openaire +1 more source
Analysis and rejection of noises from partial discharge (PD) on-site testing environment
Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials (Cat. No.03CH37417), 2004There were many kinds of interference resources in the partial discharge on-site testing environment for a power transformer. According to their spectrums, those could be classified into sinusoidal continuous noises from power carrier communication and radio systems, pulse-shaped wide-band noises including periodical and stochastical pulse-shaped ...
null Xiaoning Wang +3 more
openaire +1 more source
Partial discharge. X. PD in gas-insulated substations-measurement and practical considerations
IEEE Electrical Insulation Magazine, 1992For pt.IX see ibid., vol.7, no.6, p.5 et seq. (1991). An overview of engineering practice related to partial discharge (PD) measurements in gas-insulated substations (GISs) is provided. The following questions are addressed: why measure PD in GIS?; in which phases of the life cycle should PD be measured?; what PD measurements are presently available ...
R. Baumgartner +3 more
openaire +1 more source
Development of automatic identification method for GIS PD (Partial Discharge) defects diagnosis
2007 IEEE Lausanne Power Tech, 2007In this paper, an overview of a new GIS (gas insulated switchgear) PD (partial discharge) diagnostic algorithm for both single-defects and multi-defects in HiPDS-G (Hyundai intelligent preventive diagnostic system for GIS) developed by HHI(Hyundai Heavy Industries Co., Ltd) is given.
Young Chan Choi +4 more
openaire +1 more source
Signal extraction methods for online partial discharge (PD) measurement of power transformers
2015 IEEE 11th International Conference on the Properties and Applications of Dielectric Materials (ICPADM), 2015Wavelet transform-based Partial discharge ( PD) signal extraction methods have been widely adopted in the past ten years. However, these methods may still encounter some difficulties in online PD measurements, in which PD signals can be overwhelmed by noise.
Seo, Junhyuck, Ma, Hui, Saha, Tapan
openaire +2 more sources
European Transactions on Electrical Power, 1996
AbstractIn this paper some possibilities of further applications of a known “Streamer Partial‐Discharge Model” are proposed. These possibilities refer to the relation between the observed partial‐discharge (PD) magnitude and the applied field to the insulation.
openaire +1 more source
AbstractIn this paper some possibilities of further applications of a known “Streamer Partial‐Discharge Model” are proposed. These possibilities refer to the relation between the observed partial‐discharge (PD) magnitude and the applied field to the insulation.
openaire +1 more source
IEEE Electrical Insulation Magazine, 1992
For pt.XIV see ibid., vol.8, no.5, p.34 (1992). The effects of X-ray irradiation during partial discharge measurements are discussed. The partial discharge phenomena in cavities is detailed. A full-scale system capable of testing 138-kV-class post insulators under combined electric stress and X-ray radiation was implemented.
N. Fujimoto, S. Rizzetto, J.-M. Braun
openaire +1 more source
For pt.XIV see ibid., vol.8, no.5, p.34 (1992). The effects of X-ray irradiation during partial discharge measurements are discussed. The partial discharge phenomena in cavities is detailed. A full-scale system capable of testing 138-kV-class post insulators under combined electric stress and X-ray radiation was implemented.
N. Fujimoto, S. Rizzetto, J.-M. Braun
openaire +1 more source
2017 International Symposium on Electrical Insulating Materials (ISEIM), 2017
The authors have been investigating the deterioration characteristics of polypropylene (PP) films due to partial discharge (PD) in a closed void as a basic study of longterm deterioration of power capacitors. We reported that (1) the number of PD pulses decreased with time and then fluctuated, (2) through holes were observed only after the inception of
Ryouhei Yano +10 more
openaire +1 more source
The authors have been investigating the deterioration characteristics of polypropylene (PP) films due to partial discharge (PD) in a closed void as a basic study of longterm deterioration of power capacitors. We reported that (1) the number of PD pulses decreased with time and then fluctuated, (2) through holes were observed only after the inception of
Ryouhei Yano +10 more
openaire +1 more source
Partial discharge. XXI. Acoustic emission based PD source location in transformers
IEEE Electrical Insulation Magazine, 1995Acoustic emission-based partial discharge source location has been applied successfully to power transformers in both factory and field environments, and this method is becoming an established test procedure with a high success rate. With the aid of local utilities and utility laboratories that use acoustic emission apparatus daily, we expect further ...
openaire +1 more source
Synthesis of Partial Discharge Signals for Testing of PD Detection Algorithms in Generators
2022 International Conference on Power, Energy and Innovations (ICPEI), 2022Isara Sornsen +2 more
openaire +1 more source

