Results 21 to 30 of about 697 (183)

Airgap and stray magnetic flux monitoring techniques for fault diagnosis of electrical machines: An overview

open access: yesIET Electric Power Applications, Volume 16, Issue 3, Page 277-299, March 2022., 2022
Abstract Flux‐based fault diagnosis methods have attracted ever‐increasing attention from technical communities because of their potential diagnostic capabilities and ability to overcome weaknesses of the traditional methods such as motor current signature analysis (MCSA).
Ehsan Mazaheri‐Tehrani, Jawad Faiz
wiley   +1 more source

Design guideline for PCB integrated, high bandwidth, current slope sensing based on a planar Rogowski coil [PDF]

open access: yes, 2021
This paper shows the design process of a planar Rogowski coil integrated in the Printed-Circuit-Board (PCB) for direct current slope measurement. Focus lies on the analytic estimation of the coil parameters with respect to specific limitations and the ...
Brodatzki, Matthias   +5 more
core   +2 more sources

Textile‐based sensors for electrical current measurement in three‐phase cables

open access: yesIET Smart Grid, Volume 5, Issue 1, Page 1-11, February 2022., 2022
Abstract There is much discussion about the implementation and benefits of smart electricity networks. However, the reality is that the instrumentation needed at low voltage is too expensive for large‐scale deployment. The most highly used monitoring systems in use today are based on Rogowski coil technology, which can only be used on single‐phase ...
Dani Strickland   +5 more
wiley   +1 more source

Development of a current source resonant inverter for high current MHz induction heating

open access: yesIET Power Electronics, Volume 15, Issue 1, Page 1-10, 7 January 2022., 2022
Abstract High frequency industrial induction heating processes typically employ resonant inverters to reach high efficiency at high power levels. Advancements in wide band gap (WBG) device technology has made it feasible to push the possible frequency of these processes into the MHz regime using solid state technology. Several topologies can be applied,
Thore S. Aunsborg   +3 more
wiley   +1 more source

New Power Module Integrating Output Current Measurement Function [PDF]

open access: yes, 2017
This paper proposes a new power module concept that integrates output current measurement function to make inverters compact. The current measurement function is realized by tiny printed-circuit-board (PCB) Rogowski coils.
Hasegawa K.   +3 more
core   +2 more sources

Overview of recent progress in condition monitoring for insulated gate bipolar transistor modules: Detection, estimation, and prediction

open access: yesHigh Voltage, Volume 6, Issue 6, Page 967-977, December 2021., 2021
Abstract The insulated gate bipolar transistor (IGBT) is one of the most fragile components in power electronics converters. In order to improve the reliability of IGBTs, various measurements are taken according to the condition monitoring (CM) technique.
Meng Huang   +5 more
wiley   +1 more source

Current Commutation in a Switched Lithium‐Ion Cell used in Cascaded Half‐Bridge Multilevel Inverters

open access: yesIET Power Electronics, Volume 14, Issue 6, Page 1073-1088, 6 May 2021., 2021
Abstract In order to improve the efficiency of battery electric vehicles, the utilization of reconfigurable batteries and multilevel inverters based on low‐voltage Si MOSFETs gains growing attention. Focusing on the half‐bridge as basic switching unit, this paper examines voltage and current waveforms during switching.
Christian Hanzl   +5 more
wiley   +1 more source

Contactless measurement of electric current using magnetic sensors [PDF]

open access: yes, 2019
We review recent advances in magnetic sensors for DC/AC current transducers, especially novel AMR sensors and integrated fluxgates, and we make critical comparison of their properties.
Ripka P.
core   +1 more source

Short circuit detection and driving control with no blanking time for high voltage high power insulated gate bipolar transistors

open access: yesIET Power Electronics, Volume 14, Issue 6, Page 1138-1148, 6 May 2021., 2021
Abstract Insulated gate bipolar transistors (IGBT) short‐circuit (SC) protection is one of the most important protection methods for IGBT converter equipment. The fast detection and protection response time could reduce the permanent damage of devices, and extend their use life cycle. At present, the collector emitter voltage vce desaturation method is
Xianjin Huang   +4 more
wiley   +1 more source

Rogowski coil sensors for measuring lightning strike currents on mechanical aircraft joints [PDF]

open access: yes, 2023
© 2023 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes,creating new ...
Azpúrua Auyanet, Marco Aurelio   +3 more
core   +1 more source