Results 41 to 50 of about 1,434 (216)
A detailed description of an Automated Demand Response system is presented that can provide active distribution‐level voltage control, and sub‐second system‐wide frequency response services.
Admir Jahić +3 more
doaj +1 more source
A design approach for a low cost phasor measurement unit [PDF]
Phasor Measurement Units (PMUs) are playing more and more a crucial role for the development of the 'smartness' of power systems. In order to be efficiently used for the smart management of the power systems, a widespread diffusion of PMUs is a becoming ...
Landi C. +3 more
core +1 more source
PENEMPATAN OPTIMAL PMU (PHASOR MEASUREMENT UNITS) PADA JARINGAN DISTRIBUSI SURABAYA SELATAN [PDF]
Phasor Measurement Unit atau yang lebih dikenal dengan singkatanya yaitu PMU, adalah sebuah alat monitoring yang biasanya digunakan untuk mengukur fasor dari Tegangan dan fasor Arus pada suatu sistem tenaga listrik.
Sulistyowati, Riny +1 more
core +2 more sources
A portable system for phasor measurment units (PMU) calibration in high-voltage substations
This paper presents the advances in the development of a portable PMU standard for online calibration of PMUs installed in high voltage substations. This system is intended to be connected in parallel with the PMU under test, without disconnecting it from the network. Current and voltage sensors do not need to interrupt the service.
Daniel Slomovitz +5 more
openaire +2 more sources
Measurement and Analysis of PMU Reporting Latency for Smart Grid Protection and Control Applications
Emerging power system protection and control applications require faster-responding measurements and more accurate knowledge of the actual latency of the measurement and communications systems.
Steven M. Blair +4 more
doaj +1 more source
Parameter estimation based on the measurement data of the phasor measurement unit (PMU) is an important approach for identifying the Thévenin equivalent parameters (TEPs) of power systems. However, in the process of acquiring or transmitting data in PMU,
Anan Zhang +3 more
doaj +1 more source
Robust Identification Method for Transmission Line Parameters That Considers PMU Phase Angle Error
Accurate transmission line parameters are the basis of power system calculations. The measured phasor measurement unit (PMU) phase angle data at both ends of a line may contain large errors caused by synchronization problems, which can seriously affect ...
Ancheng Xue +6 more
doaj +1 more source
A reliability‐based optimal μ‐PMU (micro‐phasor measurement unit) placement scheme is suggested for efficient observability enhancement of smart distribution grids at steady‐state and contingencies conditions.
Arya Abdolahi +3 more
doaj +1 more source
Voltage Estimation of Active Distribution Network Using PMU Technology
As the Distributed Generation (DG) is evolving, the distribution network has undergone tremendous change. The DG sources like wind and solar are intermittent in nature.
Swathi Tangi, D. N. Gaonkar
doaj +1 more source
Monolithic UV‐ozone oxidation of Ta forms an ultrathin Ta2O5/TaOx bilayer enabling resistive switching with a vertical defect gradient. A stoichiometric surface layer over an oxygen‐deficient sublayer promotes localized filament nucleation near the top interface, enabling low‐voltage operation, and reduced cycle‐to‐cycle variability.
Seunghoon Yang +11 more
wiley +1 more source