Results 61 to 70 of about 4,943,789 (197)

Performance comparison of IEC 61850-90-5 and IEEE C37.118.2 based wide area PMU communication networks

open access: yesJournal of Modern Power Systems and Clean Energy, 2016
Dynamic operation and control of power system is being increasingly done with the help of phasor measurement unit (PMU) based wide area monitoring and control system.
Ikbal Ali   +2 more
doaj   +1 more source

Oxygen‐Scavenging‐Driven Interlayer Engineering for Balancing Linearity and Retention in IGZO Synaptic Memristors

open access: yesAdvanced Electronic Materials, EarlyView.
Oxygen‐scavenging‐induced self‐formed interlayers regulate Schottky‐barrier modulation in IGZO memristors, producing a fundamental trade‐off between synaptic update linearity and retention. A preserved AlOx interlayer moderates voltage distribution and enables gradual, nearly linear conductance updates, whereas a soft‐broken SiO2 interlayer provides a ...
Jae Woo Lee   +11 more
wiley   +1 more source

Reliable Ru‐Based CBRAM Synapses for Energy‐Efficient Neuromorphic Computing: Suppressing Filament Overgrowth and Read Noise via Ru‐Pt Alloy and AlOx Engineering

open access: yesAdvanced Electronic Materials, EarlyView.
Ru–Pt alloying suppresses filament overgrowth and an AlOx switching layer enhances reliable switching, hopping transport enables conductance tuning via hopping distance modulation, Ru7Pt3/AlOx/Pt device yields 16 low‐noise conductance states, a 2–3‐fold improvement over prior Ru‐based CBRAM, and CSNN inference on FMNIST reaches 81% accuracy with 103 ...
Sangmin Lee   +10 more
wiley   +1 more source

Dual‐Function Electrocatalysis: Simultaneous Wastewater Remediation and Hydrogen Evolution—A Comprehensive Review

open access: yesCarbon Energy, EarlyView.
Replacing the oxygen evolution reaction with the electro‐oxidation of pollutants and waste streams offers an energy‐efficient route for simultaneous hydrogen production and pollutant remediation. This review summarizes the reaction mechanisms, catalyst design principles, and emerging paired‐electrolysis strategies that govern activity, selectivity ...
Safa Al‐Yahyaey   +4 more
wiley   +1 more source

Full Coverage of Optimal Phasor Measurement Unit Placement Solutions in Distribution Systems Using Integer Linear Programming

open access: yesEnergies, 2019
Integer linear programming (ILP) has been widely applied to solve the optimal phasor measurement unit (PMU) placement (OPP) problem for its computational efficiency.
Xuebing Chen   +8 more
doaj   +1 more source

A Comprehensive Review of Fault‐Current Limiter Technologies for Smart and Resilient Power Systems

open access: yesEnergy Science &Engineering, EarlyView.
This review compares superconducting, solid‐state, and hybrid fault‐current limiters (FCLs) for modern alternating current, direct current, and hybrid grids. It shows that optimal FCL selection depends on fault characteristics, network configuration, voltage level, protection coordination, and resilience requirements rather than on a universally ...
Abdelrahman Farghly   +5 more
wiley   +1 more source

Ultra‐Efficient Memristive Voltage‐Resistance Logic Framework With Integrated Readout Strategy Based on Hafnium Zirconium Oxide

open access: yesSmall Methods, EarlyView.
Spatiotemporal efficiency is a key concern in memristor‐based logic‐in‐memory architectures, where separate read operations to access resistance states fundamentally limit efficiency. This work demonstrates that logic outputs can be directly inferred from the intrinsic discharge dynamics of a two‐terminal memristive device.
Wonwoo Kho   +12 more
wiley   +1 more source

Targeting ligament boundaries rather than alignment boundaries in augmented‐reality‐assisted total knee arthroplasty ensures comparable gait patterns between operated and contralateral limbs

open access: yesKnee Surgery, Sports Traumatology, Arthroscopy, Volume 34, Issue 10, Page 3664-3674, October 2026.
Abstract Purpose Modern personalised total knee arthroplasty (TKA) techniques aim to mimic natural knee kinematics by focusing on soft‐tissue dynamics rather than static alignment. However, a consistent definition of the optimal ligamentous balance has not yet been established.
Michael Engl   +9 more
wiley   +1 more source

Estimacija stanja u elektroenergetskom sistemu sa PMU uređajima i maliciozni napad injektiranjem loših merenja i njegova detekcija

open access: yesEnergija, Ekonomija, Ekologija
Ovaj rad istražuje značaj primene metode estimacije stanja u elektroenergetskim sistemima, posebno fokusirajući se na ulogu PMU (Phasor Measurement Unit) uređaja. Prikazane su osnovni principi i prednosti estimatora stanja u odsustvu PMU merenja, a zatim
Vladimir Bečejac   +4 more
doaj   +1 more source

A novel multi-task learning method for evaluating short-term voltage stability with incomplete PMU measurements

open access: yesComplex & Intelligent Systems, 2023
Methods for short-term voltage stability (STVS) assessment based on phasor measurement unit (PMU) data have become quite abundant. However, most of them are challenged to deal with the commonly encountered incomplete PMU data.
Tonglin Luo, Xuchu Jiang
doaj   +1 more source